RS+ EX+ AI+ AI – EX – RS – SC SC NI 9218 The NI 9218 provides 2 V excitation to loads ≥120 Ω or 3.3 V excitation to loads ≥350 Ω . The NI 9218 provides optional connections for

NI 9218 NI 9986 DSUB/LEMO RS+ EX+ AI+ EX- RS- SC SC Connecting half bridges requires the NI 9986 . The NI 9218 provides 2 V excitation to half bridges of ≥240 Ω total or 3.3 V excitation to half

The NI-9218 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2 , AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only. ...

The NI 9218 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 12 ATEX 1202658X and is IECEx UL 14.0089X certified. Each NI 9218 is marked II 3G and is suitable for use in Zone 2 hazardous

NI 9218 + - AI+ AI- The NI 9218 provides an excitation current for each channel that powers IEPE sensors. AI+ provides DC excitation and AI- provides the excitation return path. Parent topic: Measurement ...

Some products are approved for marine (shipboard) applications. To verify marine approval certification for a product, visit ni.com/product-certifications , search by model number, and click the appropriate ...

The ground terminals on a measurement adapter are connected to chassis ground when the measurement adapter is connected to the NI-9218 and the NI-9218 is installed in a chassis. Parent topic: Overview

The NI-9218 provides built-in support for the following measurement types. ±16 V ±65 mV Full-Bridge IEPE Tip NI recommends using the NI-9982 screw-terminal adapter when using built-in measurement types ...

BNC, screw terminal, or spring terminal connectivity 250 V RMS , CAT II , channel-to-earth isolation (screw terminal); 60 V DC , CAT I , channel-to-earth isolation (BNC) The NI-9215 is an analog input ...

Connect only voltages that are within the following limits. Channel-to-channel None Channel-to-earth ground Continuous 60 V DC, Measurement Category I Withstand up to 3,000 m 1,000 V RMS, verified by a ...

You can connect any combination of 3-wire or 4-wire RTDs to the NI-9216 . Each NI-9216 channel contains circuitry that automatically detects the type of RTD connected to the channel. The NI-9216 scans ...

Make sure that devices you connect to the NI-9216 are compatible with the module specifications. Parent topic: Overview

What to Use NI-9216 spring-terminal connector copper conductor wire with of insulation stripped from the end Flathead screwdriver with a 2.3 mm x 1.0 mm ( 0.09 in. x 0.04 in. ) blade, included with the ...

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI-9216 is suitable for use in hazardous locations; , and hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI-9216 in a potentially explosive ...

The NI-9216 has been evaluated as equipment under DEMKO ATEX and is IECEx certified. Each NI-9216 is marked and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ...

Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits ...

If your application is subject to high vibration, NI recommends that you use the NI-9940 backshell kit to protect connections to the NI-9216 with spring terminal . Parent topic: NI-9216 Connection Guidelines ...

To meet the EMC guidelines in this document and the Electromagnetic Compatibility specifications in the NI-9216 Datasheet , you must use the NI 9940 connector backshell kit. Figure 2. NI 9940 Connector ...

Some products are approved for marine (shipboard) applications. To verify marine approval certification for a product, visit ni.com/product-certifications , search by model number, and click the appropriate ...

This document explains how to connect to the NI-9216 . In this document, the NI-9216 with spring terminal and the NI-9216 with DSUB are referred to inclusively as the NI-9216 . Note Before you begin, read ...

NC EX0+ RTD0+ RTD0- COM EX1+ RTD1+ RTD1- COM EX2+ RTD2+ RTD2- COM EX3+ RTD3+ RTD3- COM NC NC EX4+ RTD4+ RTD4- COM EX5+ RTD5+ RTD5- COM EX6+ RTD6+ RTD6- COM EX7+ RTD7+ RTD7- COM NC 1 2 3 4

Each channel has an open thermocouple detection (OTD) circuit, which consists of a current source between the TC+ and TC- terminals.

What to Use NI-9213 spring-terminal connector 0.08 mm 2 to 1.0 mm 2 ( 28 AWG to 18 AWG ) copper conductor wire with 7 mm ( 0.28 in. ) of insulation stripped from the end Flathead screwdriver with a

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI-9213 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2 , AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations; and nonhazardous locations ...

The NI 9213 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07 ATEX 0626664X and is IECEx UL 14.0089X certified. Each NI 9213 is marked II 3G and is suitable for use in Zone 2 hazardous

If hazardous voltages are connected to the product, take the following precautions. A hazardous voltage is a voltage greater than: 30 V RMS , 42.4 V peak , or 60 V DC in DRY LOCATIONS 16 V RMS , 22.6