When I try to connect to an AXIS camera that is connected to a CompactRIO, I get the following Authentication Error: The camera is configured with password authentication and either the user name and ...

My FPGA code runs for a few seconds, then disconnects with the following error. I am trying to read data from my FPGA using either the FIFO Read or the FPGA Read method. I get the following error. Error ...

I have a Real-Time controller deployed in the field that is now occasionally switching to Safe Mode. After several reboots the system will restart in normal mode. Any idea as to why this system is now ...

I can not connect myRIO to my PC. NI myRIO USB Monitor start page does not appear after connecting myRIO. It does not shown up under Remote Systems in NI MAX, but I can find it in Device Manger as a «USB\VID_3923&PID_762F\XXXXXXXX» ...

I am developing an application that will be distributed to a remote location and I want to monitor hardware and system resources for predictive maintenance. What self-diagnostics options are available ...

When trying to load a Main VI in LabVIEW, I get errors regarding a number of missing dependencies. It seems I am missing the following NI_Real-Time Target Support.lvlib:RT CPU Load.ctl NI_Real-Time Target ...

Every hour and a half of running my Real-Time code I get the following error: (Hex 0x661) The LabVIEW Real-Time process encountered an error and restarted automatically.

I am reading from multiple channels on my cRIO and would like to send all of this data to my RT host to be processed, but want to make sure that all of the data is synchronized. How can I do this?

How can I upgrade the version of the firmware of my C Series device? Does my C series module have a firmware version?

I am running into errors when deploying my code to an Industrial Controller. What do these errors mean and how can I resolve them? Related Errors After Successful Deployment An error occurred while attempting ...

I have a cRIO application in the field that had been running continuously for months without any problems. However, last week I got the error -1950679023, causing the application to stop. Afterwards the ...

I am running my cRIO in Scan Mode but I am encountering the -65512 error. I am concerned that this is effecting the accuracy of my data, how can I fix it? I have a cRIO that uses scan engine only and at ...

When I expand Devices and Interfaces in MAX and selectRIO Device, the Serial Number, Model Name, and Model Code are displayed. How do I programatically get this information?

In the scan mode (non FGPA) of the compactRIO, the sampling rate is normally limited at 1 kHz or less. I am trying to use LabVIEW to program the compactRIO, how do I change the sampling rate?

I want to power my NI hardware with a battery instead of a traditional power supply. Is this possible?

I have an FPGA VI running on my CompactRIO. I am using the FIFO.Start method with the Invoke Method on my Real-Time program, but I get Error -61206: The configured item does not exist. Why is this happening? ...

Does LabVIEW OPC UA Toolkit support cRIO Targets? Is it possible for my Phar Lap ETS PXI controller to talk directly to my PLC using the LabVIEW OPC UA Toolkit? Can I install the OPC UA Toolkit to my Real-Time ...

I have connected my CMS device to the Network, when I test the connection from InsightCM web page, I receive the following error: The device at XX.XX.XX.XX failed to connect to NI InsightCM Server at ...

After a Software installation for the cRIO it only starts in the safe mode. Even formatting the device in NI MAX and a new installation of the Software to the cRIO didn't help. After a restart of the whole ...

I would like to deploy images to cRIO controllers that are in a remote location, without having to send out a technician on site with a laptop. Can this be done remotely?

I’ve noticed that the resource name on the Open FPGA VI Reference.vi can reference an FPGA target by either an IP address or by the target name. What is the difference in the way the FPGA target is referenced? ...

I have a C series digital input module like the NI-9411. Can I use this for counter applications, like reading a quadrature encoder?

I made my project with one type of CompactRIO (cRIO), but now I need to deploy the same project to a cRIO of a different model.Can I have my project now work with the new model, without creating a new ...

How can I install the RIO device drivers onto my hardware without having LabVIEW installed on my PC? I need to deploy my LabVIEW project to a compactRIO-9033,is there a way to install only the driver required ...

I am trying to use the System Configuration API (or the Replication and Deployment (RAD) Utility) to clone my RIO system. After successfully using Create System Image.vi, I'm seeing the following error ...

I want to use myCompactRIO(cRIO) in scan mode and acquire data from several channels at the same time. Using oneI/O variablefor each channel,dragging in from the project explorer, is tedious and not a ...

I am using the Azure cloud to store system data collected from my real-time targets. I see that there is a LabVIEW Cloud Toolkit already made to work with Azure, will this work on my real-time device running ...

I have two targets a Real Time controller and an FPGA. Additional to that I have an external device that is sharing data through ethernet. I would like to read the ethernet data directly on the FPGA.

I have a CompactRIO or sbRIO target in my LabVIEW project as a target but want to change the target to another device of the same model. How can I do this?

Showing 61-90 of 175 results