Filtered Results

Writes new pulse frequency and duty cycle pairs to a counter output task that contains a single channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx ...

Writes one or more 8-bit unsigned integer samples to a task that contains a single digital output channel. Use an instance that writes 8-bit unsigned integers for devices with up to eight lines per port. ...

Writes a single 8-bit unsigned integer sample to a task that contains a single digital output channel. Use an instance that writes 8-bit unsigned integers for devices with up to eight lines per port. LabVIEW ...

Writes multiple raw, 16-bit unsigned integer samples to a task. Use this instance for devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Writes multiple raw, 32-bit unsigned integer samples to a task. Use this instance for devices that use 32-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Configures the task to start acquiring or generating samples when an analog signal enters or leaves a range you specify. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires current excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

Configures when the DAQ device transfers data to a peripheral device, using the onboard Sample Clock of the DAQ device to control burst handshake timing, and exporting that clock for use by the peripheral ...

Sets the source of the Sample Clock, the rate of the Sample Clock, and the number of samples to acquire or generate. The device acquires or generates samples on each Sample Clock edge, but it does not ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When you use ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications do not provide a polynomial for scaling or a table of electrical and physical values. ...

Creates channel(s) that use an IEPE velocity sensor to measure velocity. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Velocity-IEPE ...

Wait until the specified timestamp has a value. Use this node to ensure the timestamp has a valid value to prevent an error when querying a timestamp value. LabVIEW NXG does not support FPGA devices Not ...

Indicates if the sample clock timing type is supported for the digital input physical channel. Not supported Not supported in VIs that run in a web application 29A5 attr29A5.html

Specifies the forward polynomial values used for calibrating the channel. Not supported Not supported in VIs that run in a web application 229F attr229F.html

Specifies the center frequency of the passband for the digital filter. Not supported Not supported in VIs that run in a web application 30C3 attr30C3.html

Specifies the digital filter coefficients. Not supported Not supported in VIs that run in a web application 30C7 attr30C7.html

Specifies the units for AI.Force.IEPESensor.Sensitivity. Not supported Not supported in VIs that run in a web application mVolts/N 15891 Millivolts per newton. mVolts/lb 15892 Millivolts per pound. 2F82 ...

Specifies the input impedance of the channel. Not supported Not supported in VIs that run in a web application 50 Ohms 50 50 Ohms. 75 Ohms 75 75 Ohms. 1 M Ohm 1000000 1 M Ohm. 10 G Ohms 10000000000 10 ...

Showing 41-60 of 2160 results
3 of 108 pages