Filtered Results

Creates a virtual channel, or set of virtual channels, and adds them to a task. If you use this node within a loop without specifying a task in, the software creates a new task in each iteration of the ...

Creates a custom scale that uses the equation y=mx+b, where x is a pre-scaled value, and y is a scaled value. The equation is identical for input and output. If the equation is in the form x=my+b, you ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Creates channel(s) that use a microphone to measure sound pressure. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Sound Pressure-Microphone).vi ...

Creates channel(s) that use an accelerometer to measure acceleration. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values ...

Creates channel(s) to measure voltage. Use this instance for custom sensors that require excitation. You can use the excitation to scale the measurement. You must configure the physical channel(s) with ...

Creates channel(s) to measure voltage. You must configure the physical channel(s) with TEDS information to use this node. If the measurement requires the use of internal excitation or you need excitation ...

Creates channel(s) to measure acceleration. Use this mode for custom sensors that require excitation. You can use the excitation to scale the measurement. LabVIEW NXG does not support FPGA devices Not ...

Creates channel(s) that use(s) an accelerometer to measure acceleration. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Acceleration-Accelerometer).vi ...

Creates channel(s) that use an LVDT to measure linear position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-LVDT).vi :/lvdaqmx.chm::/DAQmx ...

Reads the specified value from the ADC on the specified physical channel. This module requires a sweep of adjustment points obtained from the DAQmx Get 9244 Calibration Adjustment Points node. LabVIEW ...

Initializes an NI PXIe-4339 device with the specified mode, range, and excitation for calibration. Refer to the calibration procedure for your device for specific calibration instructions. LabVIEW NXG ...

Specifies the units to use to return angular position measurements from the channel. Not supported Not supported in VIs that run in a web application Degrees 10146 Degrees. Radians 10273 Radians. Ticks ...

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 30A9 attr30A9.html

Specifies whether to apply a digital filter to the digital output of the analog triggering circuitry (the Analog Comparison Event). When enabled, the analog signal must stay within the trigger window for ...

Specifies whether the task pauses while the signal is high or low. Not supported Not supported in VIs that run in a web application High 10192 High state. Low 10214 Low state. 1380 attr1380.html

Specifies the physical channels to use for pattern matching. The order of the physical channels determines the order of the pattern. If a port is included, the lines within the port are in ascending order. ...

Specifies whether subsequent read operations read all samples currently available in the buffer or wait for the buffer to become full before reading. NI-DAQmx uses this setting for finite acquisitions ...

Writes new pulse high tick counts and low tick counts to a counter output task that contains a single channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Showing 41-60 of 2006 results