Complete the following steps to set a system password. In MAX, click the Login button on the toolbar. Enter admin in the User name field. Leave the Password field blank. Note There is no default password ...

The following figure shows the reset behavior of the cRIO-904 x . Figure 6. Reset Button Behavior Press and hold RESET button fo r ≥ 5 s Press and hold RESET button for < 5 s Run Mode Safe Mode

Notice To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. Touch the antistatic package ...

Visit the following topics for information on how to create a new LabVIEW Project configured with the cRIO-904x, and how to deploy the C Series module in the Real-Time, Real-Time Scan (IO Variables), or ...

Add an exception for MAX to your network firewall or other security software by completing the following steps: On Windows 7, select Start » Control Panel » System and Security » Windows Firewall » Allow ...

Complete the following steps to find the cRIO-904 x controller in MAX. Launch MAX on the host computer. Expand Remote Systems in the configuration tree and locate your system. Select your target. Tip MAX ...

For environments with high shock and vibration, NI recommends mounting the cRIO-904 x directly on a flat, rigid surface using the mounting holes in the cRIO-904 x . What to Use cRIO-904 x M4 screws, user ...

When programming C Series modules in FPGA mode, the 40 MHz onboard clock is used as the top-level clock for your LabVIEW FPGA application and C Series module IO nodes. The 40 MHz onboard clock can be used ...

When programming C Series modules in Real-Time (NI-DAQmx) mode, the 80 MHz timebase can function as the source input to the 32-bit general-purpose counter/timers. The 80 MHz timebase is generated from ...

By using two counters, you can accurately measure a signal that might be high or low frequency. This technique is called reciprocal frequency measurement. When measuring a large range of frequencies with ...

Complete the following steps to launch the BIOS setup utility. Connect a video monitor to the USB 3.1 Type-C DisplayPort connector on the cRIO-904 x . Note In order to connect the monitor to the USB 3.1 ...

The following figures show the surface mounting dimensions for the 4-slot and 8-slot cRIO-904 x models. Figure 20. 4-slot cRIO-904 x Surface Mounting Dimensions 2× 23.7 mm (0.94 in.) 2× 20.3 mm (0.80 in.) ...

The Advanced setup menu contains BIOS settings that do not require modification for normal operation of the cRIO-904 x . If you have specific problems, such as unbootable disks or resource conflicts, you ...

The Main setup menu reports the following configuration information: BIOS Version— This value indicates the version of the controller BIOS. Build Date—This value indicates the date and time on which the ...

The counters can perform measurements of quadrature encoders that use X1, X2, or X4 encoding. A quadrature encoder can have up to three channels—channels A, B, and Z. X1 Encoding —When channel A leads ...

The counter supports two pulse encoders that have two channels—channels A and B. The counter increments on each rising edge of channel A. The counter decrements on each rising edge of channel B, as shown ...

The following figure shows the Module Immobilization accessory dimensions for the cRIO-904 x . Figure 9. 4-slot cRIO-904 x Module Immobilization Accessory Dimensions 94.2 mm (3.71 in.) 1.6 mm (0.06 in.) ...

When you use a DAC to generate a waveform, you may observe glitches on the output signal. These glitches are normal; when a DAC switches from one voltage to another, it produces glitches due to released ...

To obtain the maximum ambient temperature, you must mount the cRIO-904 x in the reference mounting configuration shown in the following image. Mounting the cRIO-904 x in the reference mounting configuration ...