Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires voltage excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When you use ...

Writes multiple raw, 32-bit signed integer samples to a task. Use this instance for devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Writes multiple raw, 8-bit unsigned integer samples to a task. Use this instance for devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Specifies for NI-DAQmx to map hardware registers to the memory space of the application, if possible. Normally, NI-DAQmx maps hardware registers to memory accessible only to the kernel. Mapping the registers ...

Specifies the order of the digital filter. Not supported Not supported in VIs that run in a web application 30C0 attr30C0.html

Specifies the maximum period (in seconds) in which the device will recognize signals. For frequency measurements, a signal with a higher period than the one set in this property will return 0 Hz. For duty ...

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 21EC attr21EC.html

Specifies the data transfer mode for the device. Not supported Not supported in VIs that run in a web application DMA 10054 Direct Memory Access. Data transfers take place independently from the application. ...

Specifies the type of trigger to use to expire a watchdog task. Not supported Not supported in VIs that run in a web application Digital Edge 10150 Trigger on a rising or falling edge of a digital signal. ...

Internal Channel Name Description _aignd_vs_aignd A differential terminal with the positive and negative terminals both connected to the ground reference for analog input. _ao0_vs_aognd A differential ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2F00 attr2F00.html

Specifies the name of a virtual channel or terminal where there is an analog signal to use as the source of the trigger. Not supported Not supported in VIs that run in a web application 1373 attr1373.html ...

Specifies for NI-DAQmx to map hardware registers to the memory space of the application, if possible. Normally, NI-DAQmx maps hardware registers to memory accessible only to the kernel. Mapping the registers ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2224 attr2224.html

On an X Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

The following table is a list of internal physical channels for all E Series devices. Different E Series devices have different subsets of channels. These channels are typically for self-calibration, and ...

On an S Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

Specifies how DAQmx Read waits for samples to become available. Not supported Not supported in VIs that run in a web application Wait For Interrupt 12523 Check for available samples when the system receives ...