Filtered Results

Filtering is one of the most commonly used signal processing techniques. Signal conditioning systems can filter unwanted signals or noise from the signal you are measuring. Use a noise filter on low-rate, ...

The half-bridge type II configuration only measures bending strain. The following figure shows how to position strain gage resistors in a bending configuration for the half-bridge type II. Half-bridge ...

An Expiration Trigger expires a watchdog task. You can use this trigger instead of the watchdog timer to signal an expiration. You can configure this trigger to occur on a digital edge.

Requirement I/O needs to be hardware-timed. All output values need to simultaneously update at the arrival of the sample clock edge. The application uses the Timed Loop. Solution Use the DAQmx Create Timing ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Creates channel(s) that use a microphone to measure sound pressure. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Gets the resistor level for lines when they are in tristate logic. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get Power Up States (Digital Pull Up ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. ...

Creates channel(s) to generate digital pulses that frequency and duty cycle define. The pulses appear on the default output terminal of the counter, unless you select a different output terminal. LabVIEW ...

Writes the specified binary value to the DAC on the specified physical channel at the specified range. Specify at least two calibration points for each physical channel and range you calibrate. Use 0 and ...

Writes a waveform that contains a single sample to a task that contains a single analog output channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx ...

Returns the reference voltage or current values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Indicates the number of Analog Output synchronization pulse sources supported by the device. Not supported Not supported in VIs that run in a web application 692 attr692.html

Specifies a string that contains arbitrary, user-defined information. This number of characters in this string can be no more than Cal.UserDefinedInfo.MaxSize. Not supported Not supported in VIs that run ...

Specifies on which slope of the source signal the Reference Trigger occurs. Not supported Not supported in VIs that run in a web application Rising 10280 Trigger on the rising slope of the signal. Falling ...

You can use software timing or hardware timing to control when a signal is generated. With hardware timing, a digital signal, such as a clock on your device, controls the rate of generation. With software ...

NI-DAQmx supports multi-device routing. You simply specify the source terminal and destination terminal. If the two terminals are on different devices, NI-DAQmx uses the trigger bus to route the signal ...

Quantization error is the inherent uncertainty in digitizing an analog value as a result of the finite resolution of the conversion process. Quantization error depends on the number of bits in the converter, ...

Showing 21-40 of 2088 results
2 of 105 pages