Filtered Results

Specifies in seconds the minimum pulse width the filter recognizes. Not supported in VIs that run in a web application 21E8 attr21E8.html

Specifies the position of the encoder when the measurement begins. This value is in the units you specify with CI.LinEncoder.Units. Not supported in VIs that run in a web application 915 attr915.html

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported in VIs that run in a web application 2212 attr2212.html

Adjusts the external calibration constants for an NI PXIe-4339 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 4339 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9225 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9225 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates a channel to measure current RMS, the average (mean) power of the acquired current. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel ...

Adjusts the external calibration constants for the analog input section of a DSA device. You must connect a known voltage to the device and specify that voltage with reference voltage. LabVIEW NXG does ...

Creates a channel to measure pulse specifications, returning the measurements as pairs of high time and low time. With the exception of devices that support multi-counter tasks, you can create only one ...

Creates a virtual channel, or set of virtual channels, and adds them to a task. You must configure the physical channel(s) with TEDS information to use this node. If you use this node within a loop without ...

Creates and configures a task that controls the watchdog timer of a device. The timer activates when you start the task. Use the digital physical channel expiration states input to set expiration states ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. When ...

Performs thermocouple lead offset nulling calibration, on the channels in the task, to compensate for offsets introduced by open thermocouple detection. Keep the measured temperature as constant as possible ...

Configures the task to acquire samples on the rising and/or falling edges of the lines or ports you specify. To detect both rising and falling edges on a line or port, wire the name of that line or port ...

Generates a specified voltage from the device. You must measure the voltage and pass that value into the DAQmx Adjust 4463 Calibration node. LabVIEW NXG does not support FPGA devices Not supported in VIs ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications do not provide a polynomial for scaling or a table of electrical and physical values. ...

Creates channel(s) that use an IEPE velocity sensor to measure velocity. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Velocity-IEPE ...

Indicates the number of digital lines in the channel. Not supported in VIs that run in a web application 2179 attr2179.html

Specifies whether to automatically reenable channels after they no longer exceed the current limit specified by DO.Overcurrent.Limit. Not supported in VIs that run in a web application 2A86 attr2A86.html ...

Showing 21-40 of 1955 results
2 of 98 pages