Filtered Results

Internal Channels for the NI 9210 Device Internal Channel Name Description _aignd_vs_aignd A referenced single-ended terminal with the positive and negative terminals both connected to the ground reference ...

Adds a cDAQ Sync connection between devices. The connection is not verified. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Add cDAQ Sync Connection.vi ...

Adjusts the external calibration constants for an NI PXIe-4303 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 4303 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9226 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9226 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9232 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9232 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use an LVDT to measure linear position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-LVDT).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. When you ...

Creates channel(s) to measure voltage. If the measurement requires the use of internal excitation or you need excitation to scale the voltage, use the Custom Voltage with Excitation measurement type for ...

Creates channel(s) to measure current. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Creates a virtual channel, or set of virtual channels, and adds them to a task. If you use this node within a loop without specifying a task in, the software creates a new task in each iteration of the ...

Creates channel(s) that use an RTD to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs ...

Creates channel(s) that use a thermocouple to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates a custom scale that scales values proportionally from a range of pre-scaled values to a range of scaled values. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates channel(s) that use a Wheatstone bridge to measure torque. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values ...

Creates a custom scale that maps an array of pre-scaled values to an array of corresponding scaled values. NI-DAQmx applies linear interpolation to values that fall between the values in the table. LabVIEW ...

Creates a virtual channel, or set of virtual channels, and adds them to a task. You must configure the physical channel(s) with TEDS information to use this node. If you use this node within a loop without ...

Creates a timing source for a Timed Loop. The timing source is based on signals a device generates. Timing sources send ticks to a timed loop. Those ticks determine when the Timed Loop executes. By default, ...

Creates channel(s) that measure voltage ratios from a Wheatstone bridge. Use this instance with bridge-based sensors that measure phenomena other than strain, force, pressure, or torque, or that scale ...

Reads one or more raw, 32-bit unsigned integer samples from a task. Use this instance with devices that use 32-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Showing 21-40 of 922 results