Filtered Results

Connect only the voltages that are within these limits: Supply voltage range (Vsup) +8 V DC to +18 V DC Maximum voltage Port-to-COM -40 V DC to +40 V DC maximum, Measurement Category I Isolation Port-to-earth ...

To meet these specifications, you must panel mount the system. Operating vibration Random 5 g RMS , 10 Hz to 500 Hz Sinusoidal 5 g , 10 Hz to 500 Hz Operating shock 30 g , 11 ms half sine;

The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted.

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

LIN cables require no termination, as nodes are terminated at the transceiver. Slave nodes typically are pulled up from the LIN bus to VBat with a 30 kΩ resistance and a serial diode. This termination ...

The maximum allowable cable length is 40 m , per the LIN specification. Parent topic: Cabling Requirements for the NI 9866

LIN cables should meet the physical medium requirement of a bus RC time constant of 5 µs . For detailed formulas for calculating this value, refer to the Line Characteristics section of the LIN specification. ...

This section deals with cabling specifications, termination resistors, cable lengths, and the number of LIN nodes that can exist in a system. Parent topic: Overview

2014/34/EU; Potentially Explosive Atmospheres (ATEX) Parent topic: NI-9866 Specifications

5 40 e 中国RoHS — NI符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于NI中国RoHS合规性信息,请登录 ni.com/environment/rohs_china 。(For information about China RoHS compliance, go to ni.com/environment/rohs_china .) Parent topic: NI-9866 ...

Showing 11-20 of 34 results