NI 9155 reconfigurable embedded chassis with integrated MXI-Express (x1) One of the following MXI-Express (x1) host systems: PXI system with MXI-Express device installed PC with MXI-Express PCI or PCIe ...

The NI 9155 requires an external power supply that meets the specifications. The NI 9155 filters and regulates the supplied power and provides power for all of the I/O modules. You must connect a power ...

HARDWARE SOFTWARE APPLICATION SUPPORT Services ni.com/services NI Community ni.com/community Support ni.com/support Software Support ni.com/info » swsupport NI 9155 Specifications ni.com/manuals NI 9155 ...

This document lists the specifications for the NI 9155 . The following specifications are typical for the -40 °C to 70 °C operating temperature range unless otherwise noted. Caution Do not operate the ...

CompactRIO NI CompactDAQ Located at ni.com/manuals RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Installs with the software NI 9208 Datasheet NI-RIO ...

Located at ni.com/manuals Installs with the software CompactRIO NI CompactDAQ RELATED INFORMATION NI 9209 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9209 Datasheet NI-DAQmx Help LabVIEW Help Services ni.com/services ...

Skip to Content Bookmarks Watch List Search Preferences Log in NI-9203 Getting Started 8-Channel, ±20 mA, 16-Bit Analog Input Module Where to Go Next Tags: Getting Started NI-9203 class="topictitle1" id="GUID-72038336-2451-4EE0-882E-00F960DADBF4__GUID-79FFFB92-3D19-4D8E-ACB9-096C8A4FD463">Where ...

CompactRIO NI CompactDAQ RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services NI 9205 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9205 Datasheet NI-DAQmx ...

The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted. All voltages are relative to COM unless otherwise noted. Caution Do not operate the NI-9205 in a manner not ...

DSUB or spring terminal connectivity 250 V RMS , CAT II , channel-to-earth isolation (spring terminal); 60 V DC , CAT I , channel-to-earth isolation (DSUB) The NI-9205 is a C Series module for use with ...

Make sure that devices you connect to the NI 9206 are compatible with the module specifications. You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single ...

You can connect a fuel cell device to the NI 9206 . Figure 6. Connecting a Fuel Cell Device to the NI 9206 NI 9206 AI23+ AI23– + – AI16+ AI16– + – AI7+ AI7– + – AI0+ AI0– +

What to Use NI 9206 spring-terminal connector 0.08 mm 2 to 1.0 mm 2 ( 28 AWG to 18 AWG ) copper conductor wire with 7 mm ( 0.28 in. ) of insulation stripped from the end Flathead screwdriver with

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI 9206 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2 , AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations; and nonhazardous

The NI 9206 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 03 ATEX 0324020X and is IECEx UL 14.0089X certified. Each NI 9206 is marked II 3G and is suitable for use in Zone 2 hazardous

If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. Caution Ensure that hazardous ...

If your application is subject to high vibration, NI recommends that you use the NI 9941 backshell kit to protect connections to the NI 9206 .

Channel-to-channel None Channel-to-earth ground Continuous U.S. (UL 61010-1) 600 V DC, Measurement Category I Europe (IEC 61010-1) 400 V DC, Measurement Category I Withstand 2,500 V PK , verified by a ...

Some products are Lloyd’s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd’s Register certification for a product, visit ni.com/certification and search for the LR certificate, ...

CompactRIO NI CompactDAQ Located at ni.com/manuals RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Installs with the software NI 9212 Datasheet NI-RIO ...

DSUB or push-in spring terminal connectivity 250 V RMS , CAT II , channel-to-earth isolation (spring terminal); 60 V DC , CAT I , channel-to-earth isolation (DSUB) -40 °C to 70 °C operating, 5 g vibration, ...

The NI-9203 provides connections for 8 analog input channels. Figure 1. NI-9203 Pinout AI0 AI1 AI2 AI3 AI4 AI5 AI6 AI7 NC COM 0 1 2 3 4 5 6 7 8 9 Each channel has an AI terminal to

You can connect single-ended current signals to the NI-9203 . Figure 2. Connecting Single-Ended Current Signals to the NI-9203 Note You must use 2-wire ferrules to create a secure connection when connecting ...

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI-9203 is suitable for use in hazardous locations; , and hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI-9203 in a potentially explosive ...

The NI-9203 has been evaluated as equipment under DEMKO ATEX and is IECEx certified. Each NI-9203 is marked and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ...

Channel-to-channel None Channel-to-earth ground up to 2,000 m altitude Continuous 250 V RMS, Measurement Category II Withstand 2,300 V RMS, verified by a 5 s withstand test Channel-to-earth ground up to ...