Connect only voltages that are within the following limits: Between any two terminals ±30 V maximum Isolation Channel-to-channel None Channel-to-earth ground Continuous 60 V DC, Measurement Category I ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

Typical IEPE sensors have a case that is electrically isolated from the IEPE electronics, so connecting the sensor to the NI 9234 results in a floating connection even though the case of the sensor is ...

The NI-9234 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07 ATEX 0626664X and is IECEx UL 14.0089X certified. Each NI-9234 is marked II 3G and is suitable for use in Zone 2 hazardous locations, ...

Spring terminal connectivity 60 V DC , CAT I , channel-to-earth isolation 8 channels, 10 kS/s per channel, simultaneous dynamic strain analog input ±29.4 mV/V input range, 24-bit resolution Built-in voltage ...

Read the NI-9236 Safety, Environmental, and Regulatory Information and complete the software and hardware installation procedures in your chassis documentation.

The NI-9236 provides connections for eight 350 Ω quarter-bridge input channels. Figure 1. NI-9236 Pinout 1 2 3 4 5 6 7 8 9 10 11 12 EXC1 AI1 RC1 EXC3 AI3 RC3 EXC5 AI5 RC5 EXC7 AI7 RC7 EXC0

You can connect quarter-bridge sensors to the NI-9236 . NI 9236 EXC AI RC 1 1 2 You must connect each EXC terminal to only one strain gage to maintain the channel-to-channel crosstalk performance of the ...

What to Use NI-9236 spring-terminal connector copper conductor wire with of insulation stripped from the end Flathead screwdriver with a 2.3 mm x 1.0 mm ( 0.09 in. x 0.04 in. ) blade, included with the ...

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI-9236 is suitable for use in hazardous locations; , and hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI-9236 in a potentially explosive ...

The NI-9236 has been evaluated as equipment under DEMKO ATEX and is IECEx certified. Each NI-9236 is marked and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ...

If your application is subject to high vibration, NI recommends that you use the NI-9965 backshell kit to protect connections to the NI-9236 . Parent topic: Connecting the NI-9236

Connect only voltages that are within the following limits: Maximum working voltage, channel-to-earth ground Continuous Up to 2,000 m altitude 300 Vrms , Measurement Category III Up to 5,000 m altitude ...

Table 1. NI-9237 Signal Descriptions Signal Name Description AI+ Positive analog input signal connection AI- Negative analog input signal connection RS+ Positive remote sensing connection RS- Negative ...

Connect only voltages that are within the following limits. Between any two pins ±30 V maximum Isolation, channel-to-channel None Isolation, channel-to-earth ground Up to 3,000 m Continuous 60 VDC, Measurement ...

When you insert or remove a new sensor from the NI-9237 , slight changes in the excitation voltages can cause a mismatch between the internal half-bridge completion resistors and the half-bridge sensors, ...

You can connect a full bridge to the NI-9237 . Figure 2. Connecting a Full Bridge to the NI-9237 You also can connect floating signals to the NI-9237 . If you connect floating signals to the NI-9237 , ...

You can connect a quarter bridge to the NI-9237 by adding a resistor externally to create a half bridge. Figure 4. Connecting a Quarter Bridge to the NI-9237 You also can use a quarter bridge with the ...

Some products are approved for marine (shipboard) applications. To verify marine approval certification for a product, visit ni.com/product-certifications , search by model number, and click the appropriate ...

This document explains how to connect to the NI-9237 . In this document, the NI-9237 with RJ-50 and the NI-9237 with DSUB are referred to inclusively as the NI-9237 . Note Before you begin, read the NI-9237 ...

Ensure that the environment in which you are using the NI-9237 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C Operating humidity (IEC 60068-2-30) ...

Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and compromise the built-in safety protection. Attention Suivez ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

You can connect TEDs sensors to the NI-9237 . Figure 5. Connecting TEDS Sensors to the NI-9237 Ensure that neither the TEDS data (T+) nor the TEDS return (T-) signal is tied in common to any AI signals ...

4 channels, 50 kS/s per channel simultaneous AI ±25 mV/V input range, 24-bit resolution Programmable half- and full-bridge completion with up to 10 V internal excitation 60 VDC, Category I bank isolation ...

Install cables for the NI-9238 in accordance with the following requirements: Connect the cable shield to the chassis ground (grounding screw of the chassis). Install an EMI Noise-Suppression Ferrite (part ...

Make sure that devices you connect to the NI-9238 are compatible with the module specifications. You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single ...

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...