Filtered Results

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 2202 attr2202.html

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Specifies the logic level behavior on the input line. Not supported Not supported in VIs that run in a web application Logic Level Pull-up 16064 High logic. None 10230 Supply no excitation to the channel. ...

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 30A5 attr30A5.html

Specifies the units to use to return temperature measurements from the channel. Not supported Not supported in VIs that run in a web application Deg C 10143 Degrees Celsius. Deg F 10144 Degrees Fahrenheit. ...

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 2273 attr2273.html

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Specifies the maximum number of simultaneous USB transfers used to stream data. Modify this value to affect performance under different combinations of operating system and device. Not supported Not supported ...

Specifies the divisor for an external counter timebase. You can divide the counter timebase in order to measure slower signals without causing the count register to roll over. Not supported Not supported ...

Specifies the terminal of the signal to use as the timebase of the digital filter. Not supported Not supported in VIs that run in a web application 2F10 attr2F10.html

Specifies the terminal of the timebase to use for the counter. Typically, NI-DAQmx uses one of the internal counter timebases when performing counter measurements. Use this property to specify an external ...

Specifies the logic level behavior on the count reset line. Not supported Not supported in VIs that run in a web application Logic Level Pull-up 16064 High logic. None 10230 Supply no excitation to the ...

Specifies the data transfer mode for the channel. Not supported Not supported in VIs that run in a web application DMA 10054 Direct Memory Access. Data transfers take place independently from the application. ...

Specifies the input terminal of the signal to measure. Not supported Not supported in VIs that run in a web application 2F0C attr2F0C.html

Specifies whether to enable duplicate count prevention for the channel. Duplicate count prevention is enabled by default. Setting CI.Prescaler disables duplicate count prevention unless you explicitly ...

Specifies in seconds the minimum pulse width the digital filter recognizes. Not supported Not supported in VIs that run in a web application 30E1 attr30E1.html

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 220A attr220A.html

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 30E2 attr30E2.html

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 220D attr220D.html ...

Specifies the terminal to which signal A is connected. Not supported Not supported in VIs that run in a web application 30DD attr30DD.html

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 30DE attr30DE.html

Specifies the number of pulses the encoder generates per revolution. This value is the number of pulses on either signal A or signal B, not the total number of pulses on both signal A and signal B. Not ...

Specifies the units to use to return angular velocity counter measurements. Not supported Not supported in VIs that run in a web application RPM 16080 Revolutions per minute. Radians/s 16081 Radians per ...

Specifies the units to use to return pulse width measurements. Not supported Not supported in VIs that run in a web application Seconds 10364 Seconds. Ticks 10304 Timebase ticks. From Custom Scale 10065 ...

Specifies the counter behavior when data is read but a new value was not detected during a sample clock. Not supported Not supported in VIs that run in a web application Repeated Data 16062 Repeat the ...

Specifies between which edges to measure the frequency of the signal. Not supported Not supported in VIs that run in a web application Rising 10280 Rising edge(s). Falling 10171 Falling edge(s). 799 attr799.html ...

Specifies the input terminal of the signal to measure. Not supported Not supported in VIs that run in a web application 18A2 attr18A2.html

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 221A attr221A.html

Specifies the units to use to return frequency measurements. Not supported Not supported in VIs that run in a web application Hz 10373 Hertz. Ticks 10304 Timebase ticks. From Custom Scale 10065 Units a ...

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 221B attr221B.html

Showing 271-300 of 2179 results