Filtered Results

Creates channel(s) to measure resistance. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Resistance).vi :/lvdaqmx.chm::/DAQmx ...

Updates power up states for analog physical channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Analog With Output Type).vi ...

Sets the digital logic family to use when the device powers up. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Digital Logic Family).vi ...

Sets the resistor level to pull up or pull down for lines when they are in tristate logic. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. When ...

Creates channel(s) to generate digital pulses that frequency and duty cycle define. The pulses appear on the default output terminal of the counter, unless you select a different output terminal. LabVIEW ...

Creates channel(s) to generate digital pulses defined by the amount of time the pulse is at a high state and the amount of time the pulse is at a low state. The pulses appear on the default output terminal ...

Creates channel(s) to duty cycle of a digital pulse. Connect the input signal to the default input terminal of the counter, unless you select a different input terminal. With the exception of devices that ...

Creates a channel to measure the frequency of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this node, because ...

Creates a channel that uses a special purpose counter to take a timestamp and synchronizes that counter to a GPS receiver. With the exception of devices that support multi-counter tasks, you can create ...

Creates a channel to measure the period of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this node, because ...

Creates a channel to measure pulse specifications, returning the measurements as pairs of frequency and duty cycle. With the exception of devices that support multi-counter tasks, you can create only one ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Creates a channel to measure pulse specifications, returning the measurements as pairs of high time and low time. With the exception of devices that support multi-counter tasks, you can create only one ...

Reads one or more raw, 8-bit unsigned integer samples from a task. Use this instance with devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more floating-point samples from a task that contains a single analog input channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read ...

Reads a single floating-point sample from each channel in a task that contains one or more analog input channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Reads a waveform that contains a single sample from each channel in a task that contains one or more analog input channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a ...

Showing 181-200 of 2088 results
10 of 105 pages