Filtered Results

Specifies constraints to apply when the counter generates pulses. Constraining the counter reduces the device resources required for counter operation. Constraining the counter can also allow additional ...

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 30AB attr30AB.html

Indicates the current state of the out terminal of the counter. Not supported Not supported in VIs that run in a web application High 10192 High state. Low 10214 Low state. 149 attr149.html

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 21EC attr21EC.html

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 21ED attr21ED.html

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 21EF attr21EF.html ...

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 21EE attr21EE.html

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Specifies the value by which to divide the input signal if CI.Period.MeasMeth is Large Range with 2 Counters. The larger the divisor, the more accurate the measurement. However, too large a value could ...

Specifies whether to enable averaging mode for Sample Clock-timed period measurements. Not supported Not supported in VIs that run in a web application 2ED1 attr2ED1.html

Specifies whether to enable bus mode for digital filtering. If you set this property to TRUE, NI-DAQmx treats all lines that use common filtering settings as a bus. If any line in the bus has jitter, all ...

Specifies in seconds the minimum pulse width the filter recognizes as a valid high or low state transition. Not supported Not supported in VIs that run in a web application 21D7 attr21D7.html

Specifies the path to the TDMS file to which you want to log data. If the file path is changed while the task is running, this takes effect on the next sample interval (if Logging.SampsPerFile has been ...

Specifies the terminal of the signal to use as the timebase of the digital filter. Not supported Not supported in VIs that run in a web application 2ED4 attr2ED4.html

Specifies the size, in samples, in which data will be written to disk. The size must be evenly divisible by the volume sector size, in bytes. Not supported Not supported in VIs that run in a web application ...

Specifies whether to invert the lines in the channel. If you set this property to TRUE, the lines are at high logic when off and at low logic when on. Not supported Not supported in VIs that run in a web ...

Specifies the divisor to apply to the signal you connect to the counter source terminal. Pulse generations defined by frequency or time take this setting into account, but pulse generations defined by ...

Specifies how many samples to write to each file. When the file reaches the number of samples specified, a new file is created with the naming convention of _####.tdms, where #### starts at 0001 ...

Specifies the frequency of the pulses to generate. This value is in the units you specify with CO.Pulse.Freq.Units or when you create the channel. Not supported Not supported in VIs that run in a web application ...

Specifies in seconds the amount of time to wait before generating the first pulse. Not supported Not supported in VIs that run in a web application 299 attr299.html

Showing 181-200 of 2006 results
10 of 101 pages