Filtered Results

Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Warranted specifications account for measurement uncertainties, ...

These specifications apply to the PXIe-5110 with 64 MB and 512 MB of memory. Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by ...

Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Warranted specifications account for measurement uncertainties, ...

Your device must be externally calibrated at least once every two years in order to maintain adherence to published specifications. For the PXIe-5163, external calibration yields the following benefits: ...

PXIe, 200 MHz, 1 GS/s, 14-bit PXI Oscilloscope Input voltage range up to 100 Vpk-pk High voltage offsets allow for measurements up to 250 V Two simultaneously sampled 14-bit channels Data transfer of 3.2 ...

The PXIe-5163 includes general purpose digital lines. You can connect to these resources through either the front panel SMB PFI 0 or AUX 0 I/O connector using a supported cable and accessory. NI provides ...

You can use the SCB-19 connector block to connect digital signals to the AUX 0 connector on the PXIe-5163 front panel. Refer to the following figure and table for information about the SCB-19 signals when ...

The following table shows the signals available for export from the PXIe-5163 and the lines to which they can be routed. Source Destination PXI_Trig <0..6> AUX 0 CLK OUT AUX 0 PFI <0..7> SMB PFI 0 Exported ...

The PXIe-5163 uses four analog-to-digital converter (ADC) cores per channel, sampling at different equally spaced 250 MHz clock phases. The ADC samples are then recombined to allow for a 1 GS/s effective ...

Edge An edge trigger occurs when a signal crosses a trigger threshold you specify. Hysteresis A hysteresis trigger includes an additional hysteresis value on either side of a trigger threshold you specify ...

The PXIe-5164 supports external calibration and self-calibration. The PXIe-5164 supports external adjustment of the following parameters: DC gain and offset of all DC-coupled paths DC offset of all AC-coupled ...

Front Panel Connectors Signal Connector Type Description CH 0 and CH 1 BNC female Analog input connection; digitizes data and triggers acquisitions. CLK IN SMB Imports an external Reference Clock or Sample ...

For optimum performance, use self-calibration in any of the following circumstances: Temperature has changed more than 5 °C from the previous self-calibration 90 days have elapsed since the previous self-calibration ...

The PXIe-5164 will go through thermal shutdown if the temperature exceeds 96°C. Reboot your system to re-enable your device after thermal shutdown. The thermal shutdown error continues to report until ...

The PXIe-5164 uses four analog-to-digital converter (ADC) cores per channel, sampling at different equally spaced 250 MHz clock phases. The ADC samples are then recombined to allow for a 1 GS/s effective ...

By default, this functionality is only available when using NI-SCOPE. The PXIe-5164 supports analog edge, hysteresis, and window trigger types.

PXIe, 4- or 8-Channel, 100 MHz Bandwidth, 14-Bit, Reconfigurable Oscilloscope User-programmable FPGA 250 MS/s sample rate 3.2 GB/s data transfer to host 50 Ω input impedance Software-selectable AC/DC coupling ...

Connector Descriptions Connector Description CH 0 to CH 3 Analog input terminal CH 4 to CH 7 Additional analog input terminals on the PXIe-5170 (8 CH) AUX I/O Sample Clock or Reference Clock input, Reference ...

PXIe, 8-Channel, 250 MHz Bandwidth, 14-Bit, Reconfigurable PXI Oscilloscope User-programmable FPGA 250 MS/s sample rate 3.2 GB/s data transfer to host Software-selectable AC/DC coupling 1.5 GB RAM

Connector Descriptions Connector Description CH 0 to CH 7 Analog input terminal AUX I/O Sample Clock or Reference Clock input, Reference Clock output, bidirectional digital PFI, and 3.3 V power output ...

The PXIe-5172 supports external calibration and self-calibration. The PXIe-5172 supports external adjustment of the following parameters: DC gain and offset of all DC-coupled paths DC offset of all AC-coupled ...

The PXIe-5172 includes general purpose digital lines. You can connect to these resources through the front panel AUX I/O port using a supported cable and accessory, such as the SCB-19 (NI part number 783959-01). ...

You can use the Mini-HDMI Breakout Cable to 6 BNC to connect digital signals to the AUX 0 connector on the PXIe-5172 front panel. Refer to the following figure and table for information about the Mini-HDMI ...

You can use the SCB-19 connector block to connect digital signals to the AUX 0 connector on the PXIe-5172 front panel. Refer to the following figure and table for information about the SCB-19 signals when ...

Front Panel Connectors Signal Connector Type Description CH 0 through CH 7 SMB Analog input connection; digitizes data and triggers acquisitions AUX 0 MHDMR Sample Clock or Reference Clock input, Reference ...

This functionality is only available when using NI-SCOPE. The following table shows the signals available for export from the PXIe-5172 and the lines to which they can be routed. Source Destination PXI_Trig ...

Before running self-calibration, warm up the PXIe-5172 for at least 15 minutes. Warm-up begins after the chassis and controller or PC is powered and NI-SCOPE is loaded and recognizes the PXIe-5172. In ...

For the PXIe-5172, self-calibration yields the following benefits: Characterizes onboard Sample Clock phase adjustment circuitry. Characterizes onboard intermodule synchronization measurement circuitry ...

The PXIe-5172 will go through thermal shutdown if the onboard temperature exceeds 96°C. The PXIe-5172 measures the temperature at the device FPGA to evaluate thermal conditions. You can read the value ...

By default, this functionality is only available when using NI-SCOPE. The PXIe-5172 supports analog edge, hysteresis, and window trigger types.

Showing 1-30 of 152 results
1 of 6 pages