Applies offset, in seconds, to the sample clock relative to the reference clock when using the onboard clock. Each time this node is called, the sample clock is offset from the reference clock by the specified ...

Extracts a session that can be passed to NI-TClk nodes. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously ...

Performs initialization actions with extra options. This node performs the following initialization actions: Creates a new IVI instrument driver session and, optionally, sets the initial state of the following ...

For background on manual adjustment, refer to Manual Adjustment of NI-TClk Synchronization. Before beginning this procedure, complete the following: Self-calibrate all instruments in your test system. ...

Performs a hard reset of the device. During a hard reset, acquisition stops, all routes are released, RTSI and PFI lines are tri-stated, FPGAs are reset, hardware is configured to its default state, and ...

Resets the oscillator to a known state and resets session attributes to values specified in the IVI configuration store. This function uses default parameters to perform a software reset on the device. ...

Resets the digitizer to its default state. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously allocated by ...

Returns the revision numbers of the instrument driver and instrument firmware. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument ...

Self-calibrates most NI digitizers, including all SMC-based devices. Not supported Not supported in VIs that run in a web application Self-Calibrating SMC-Based Devices For SMC-based devices, if the self-calibration ...

Runs the device self-test routine and returns the test result(s). Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously ...

Sends the selected trigger to the digitizer. You can also call this node to override a misused edge, digital, or hysteresis reference trigger. Not supported Not supported in VIs that run in a web application ...

For the PXI-5900 PXI RF Amplifier, this node connects the specified channel to the calibration source and sets the calibration source to ±10 V or to GND. Not supported Not supported in VIs that run in ...

Allows you to store miscellaneous information in the EEPROM of a device. For example, you can store an operator ID for the person or company performing a calibration. The information is stored immediately. ...

When you install NI-SCOPE on a 64-bit system, you can monitor, control, and record measurements from supported devices using InstrumentStudio. InstrumentStudio is a software-based front panel application ...

Adds one measurement to the list of processing steps that are completed before the measurement. Not supported Not supported in VIs that run in a web application Processing Measurements The processing is ...

For the PXIe/PXI/PCI-5105, this function calibrates the external clock digital clock managers (DCMs). DCM calibration ensures that data can be sampled at the correct time in the clock period. Not supported ...

Generates the CableSense signal on all channels of an oscilloscope for which the signal is enabled, as configured by the CableSense Mode property. The input impedance of the channel(s) to convey the CableSense ...

Clears the list of processing steps assigned to the given channel. Not supported Not supported in VIs that run in a web application Processing StepsThe processing steps are added with Add Waveform Processing, ...

Configures how the digitizer acquires data and fills the waveform record. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session ...

Configures the properties that control the electrical characteristics of the channel. This function configures the input impedance and the bandwidth. Not supported Not supported in VIs that run in a web ...

Configures the custom coefficients for the equalization finite impulse response (FIR) filter on the device. The FIR filter is designed to compensate the input signal for artifacts introduced to the signal ...

Configures common properties for hysteresis triggering. A hysteresis trigger includes an additional hysteresis value on either side of a trigger threshold you specify that a signal must cross before a ...

Configures common properties for runt triggering. A runt trigger occurs when both the leading edge and trailing edge of a pulse cross only one of two trigger thresholds you specify and with a polarity ...

Clock (G Dataflow) NI-SCOPE 17.0 NI-SCOPE 17.5, 18.0 NI-SCOPE 18.1 NI-SCOPE 18.5 NI-SCOPE 18.6 NI-SCOPE 18.7, 19.0 NI-SCOPE 19.1, 19.5, 19.6 Clock functions for NI-SCOPE. Adjust Sample Clock Relative Delay ...

Reset (G Dataflow) NI-SCOPE 17.5, 18.0 NI-SCOPE 18.1 NI-SCOPE 18.5 NI-SCOPE 18.6 NI-SCOPE 18.7, 19.0 NI-SCOPE 19.1, 19.5, 19.6 Resets the device. Reset » Reset Resets the digitizer to its default state. ...