Aborts an acquisition without changing the settings on the digitizer. Use this function if the digitizer times out while waiting for a trigger. Not supported Not supported in VIs that run in a web application ...

Adds one measurement to the list of processing steps that are completed before the measurement. Not supported Not supported in VIs that run in a web application Processing Measurements The processing is ...

For the PXI-5900 PXI RF Amplifier, this node calibrates the gain and offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize ...

Externally calibrates the compensation attenuator. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External Calibration. ...

For the PXIe/PXI/PCI-5105, this function calibrates the external clock digital clock managers (DCMs). DCM calibration ensures that data can be sampled at the correct time in the clock period. Not supported ...

For the PXIe-5622, this node calibrates the frequency response of the device. This node is called multiple times, once for each frequency point in the sweep. You must supply the stimulus frequency, in ...

Externally calibrates the vertical offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External Calibration. The handle ...

Externally calibrates the vertical range for the specified channel and vertical range setting. Not supported Not supported in VIs that run in a web application session in The instrument handle that you ...

Calibrates the sample rate of SMC-based digitizers. Use this node only when following the external calibration procedure for your device. This node adjusts the frequency of the voltage controlled crystal ...

Changes the password used to begin an external calibration session. This node verifies old password against the password stored in the device's EEPROM. If the two passwords match, the node stores the new ...

Retrieves a waveform the digitizer has acquired for the specified channel. This function returns scaled voltage data in a waveform data type that includes timing information. Not supported Not supported ...

Retrieves data that the oscilloscope has acquired from a previously initiated acquisition.

Returns the actual number of points the digitizer acquires for each channel. Not supported Not supported in VIs that run in a web application Determining Waveform Size After configuring the digitizer for ...

Returns the sample mode the digitizer is currently using. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously ...

Retrieves the custom coefficients for the equalization FIR filter on the device. This filter is designed to compensate the input signal for artifacts introduced to the signal outside of the device. Because ...

Gets the frequency response of the digitizer for the current configurations of the channel attributes. This node can be used only with high-speed digitizers that support onboard signal processing (OSP). ...

Extracts a session that can be passed to NI-TClk nodes. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously ...

Returns the effective sample rate, in samples per second, of the acquired waveform using the current configuration. Not supported Not supported in VIs that run in a web application session in Handle that ...

Returns a writer endpoint that can be used with NI-P2P to configure a peer-to-peer stream with a digitizer endpoint. Not supported Not supported in VIs that run in a web application session in Handle that ...

Clears the list of processing steps assigned to the given channel. Not supported Not supported in VIs that run in a web application Processing StepsThe processing steps are added with Add Waveform Processing, ...

Ends an niScope instrument I/O session and performs closing actions. This function performs the following actions: Closes the instrument I/O session. Destroys the IVI session and all of its properties ...

Returns coefficients that can be used to scale binary data to volts. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External ...

Configures how the digitizer acquires data and fills the waveform record. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session ...

Performs initialization actions with extra options. This node performs the following initialization actions: Creates a new IVI instrument driver session and, optionally, sets the initial state of the following ...

Initiates a waveform acquisition. After you call this function, the digitizer leaves the Idle state and waits for a trigger. The digitizer acquires a waveform for each channel you enable with Configure ...

Returns whether or not the device is ready to be used. Not supported Not supported in VIs that run in a web application resource name The device name assigned by Measurement & Automation Explorer (MAX). ...

Takes an acquisition from a specified channel and retrieves the initial X value, which includes the time-to-digital conversion. This node performs the acquisition by calling Read Waveform 2,000 times. ...