Fetches a waveform from the digitizer and performs the specified waveform measurement. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument ...

Obtains a waveform from the digitizer and returns the specified measurement voltage data for a single channel and record. Not supported Not supported in VIs that run in a web application session in Handle ...

Retrieves the waveform the digitizer has acquired for multiple channels and records. This function returns scaled voltage waveforms in a cluster that includes timing information. Not supported Not supported ...

Retrieves data from multiple channels and records. This function returns a two-dimensional array of complex, scaled waveforms. Not supported Not supported in VIs that run in a web application session in ...

Retrieves data from multiple channels and records. This function returns a two-dimensional array of binary 32-bit waveforms. Not supported Not supported in VIs that run in a web application session in ...

Retrieves data from multiple channels and records. This function returns a two-dimensional array of binary 8-bit waveforms. Not supported Not supported in VIs that run in a web application session in Handle ...

Retrieves data from a single channel and record. This function returns a one-dimensional array of binary 32-bit values. Not supported Not supported in VIs that run in a web application session in Handle ...

Retrieves data that the oscilloscope has acquired from a previously initiated acquisition.

Takes an acquisition from a specified channel and retrieves the initial X value, which includes the time-to-digital conversion. This node performs the acquisition by calling Read Waveform 2,000 times. ...

Sets, gets, or checks properties relating to NI-SCOPE. Not supported Not supported in VIs that run in a web application niscope in Identifies a particular NI-SCOPE instrument session. error in Error conditions ...

Generates a 1 kHz square wave signal for probe compensation. Most oscilloscopes output the probe compensation signal on PFI 1. Not supported Not supported in VIs that run in a web application This node ...

Aborts an acquisition without changing the settings on the digitizer. Use this function if the digitizer times out while waiting for a trigger. Not supported Not supported in VIs that run in a web application ...

Returns status information indicating whether an acquisition is in progress, complete, or unknown. Not supported Not supported in VIs that run in a web application session in Handle that identifies the ...

Adds one measurement to the list of processing steps that are completed before the measurement. Not supported Not supported in VIs that run in a web application Processing Measurements The processing is ...

For the PXI-5900 PXI RF Amplifier, this node calibrates the gain and offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize ...

Externally calibrates the compensation attenuator. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External Calibration. ...

For the PXIe/PXI/PCI-5105, this function calibrates the external clock digital clock managers (DCMs). DCM calibration ensures that data can be sampled at the correct time in the clock period. Not supported ...

For the PXIe-5622, this node calibrates the frequency response of the device. This node is called multiple times, once for each frequency point in the sweep. You must supply the stimulus frequency, in ...

Externally calibrates the vertical offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External Calibration. The handle ...

Externally calibrates the vertical range for the specified channel and vertical range setting. Not supported Not supported in VIs that run in a web application session in The instrument handle that you ...

Configures the relative sample clock delay, in seconds, when using the internal clock. Each time this node is called, the Sample clock is delayed from the Reference clock by the specified amount of time. ...

Calibrates the sample rate of SMC-based digitizers. Use this node only when following the external calibration procedure for your device. This node adjusts the frequency of the voltage controlled crystal ...

Automatically configures the digitizer. When you call this node, the digitizer senses the input signal and automatically configures many of the instrument settings. If a signal is detected on a channel, ...

Changes the password used to begin an external calibration session. This node verifies old password against the password stored in the device's EEPROM. If the two passwords match, the node stores the new ...

Clears the waveform statistics on the channel and measurement you specify. Clears the statistical information and the multi-acquisition array measurements. Every time a measurement is called, the statistics ...

Clears the list of processing steps assigned to the given channel. Not supported Not supported in VIs that run in a web application Processing StepsThe processing steps are added with Add Waveform Processing, ...