Clock (G Dataflow) NI-SCOPE 17.0 NI-SCOPE 17.5, 18.0 NI-SCOPE 18.1 NI-SCOPE 18.5 NI-SCOPE 18.7, 19.0 NI-SCOPE 19.1, 19.5, 19.6 NI-SCOPE 20.0, 20.1 Clock functions for NI-SCOPE. Adjust Sample Clock Relative ...

Takes an acquisition from a specified channel and retrieves the initial X value, which includes the time-to-digital conversion. This node performs the acquisition by calling Read Waveform 2,000 times. ...

Sets, gets, or checks properties relating to NI-SCOPE. Not supported Not supported in VIs that run in a web application niscope in Identifies a particular NI-SCOPE instrument session. error in Error conditions ...

Generates a 1 kHz square wave signal for probe compensation. Most oscilloscopes output the probe compensation signal on PFI 1. Not supported Not supported in VIs that run in a web application This node ...

Disables the 1 kHz square wave signal for probe compensation. Not supported Not supported in VIs that run in a web application This node does not support the following hardware: PXIe-5185 PXIe-5186 PXIe-5622 ...

Initiates an acquisition, waits for it to complete, and performs the specified waveform measurement for a single channel and record. Not supported Not supported in VIs that run in a web application session ...

Initiates an acquisition and returns a one-dimensional array of LabVIEW waveform data types that includes timing information. Not supported Not supported in VIs that run in a web application session in ...

Initiates an acquisition, waits for it to complete, and retrieves the data for multiple channels and records. Not supported Not supported in VIs that run in a web application session in Handle that identifies ...

Initiates an acquisition, waits for it to complete, and performs the specified waveform measurement for multiple channels and records. Not supported Not supported in VIs that run in a web application session ...

Initiates an acquisition, waits for it to complete, and retrieves the data for a single channel and record. Not supported Not supported in VIs that run in a web application session in Handle that identifies ...

Returns the waveform the digitizer acquires for the specified channel. This function initiates an acquisition that returns a scaled voltage waveform in a waveform data type that includes timing information. ...

Initiates an acquisition, waits for it to complete, and acquires data.

Performs a hard reset of the device. During a hard reset, acquisition stops, all routes are released, RTSI and PFI lines are tri-stated, FPGAs are reset, hardware is configured to its default state, and ...

Resets the oscillator to a known state and resets session attributes to values specified in the IVI configuration store. This function uses default parameters to perform a software reset on the device. ...

Resets the digitizer to its default state. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously allocated by ...

Returns the revision numbers of the instrument driver and instrument firmware. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument ...

Self-calibrates most NI digitizers, including all SMC-based devices and most Traditional NI-DAQ (Legacy) devices. Not supported Not supported in VIs that run in a web application Self-Calibrating SMC-Based ...

Runs the device self-test routine and returns the test result(s). Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously ...

Sends the selected trigger to the digitizer. You can also call this node to override a misused edge, digital, or hysteresis reference trigger. Not supported Not supported in VIs that run in a web application ...

For the PXI-5900 PXI RF Amplifier, this node connects the specified channel to the calibration source and sets the calibration source to ±10 V or to GND. Not supported Not supported in VIs that run in ...

Aborts the current task, opens the data channel relays, and releases all RTSI and PFI lines. Use this function for a condition where you want to stop the current acquisition and disable the channels. Not ...

Takes the error code returned by NI-SCOPE functions and returns the interpretation as a user-readable string. You can pass VI_NULL as the instrument handle, which is useful to interpret errors if Initialize ...

Configures the digitizer to generate a signal that other devices can detect when configured for digital triggering or sharing clocks. Not supported Not supported in VIs that run in a web application Using ...

Obtains multiple waveforms from the digitizer and returns the specified array measurement for multiple channels and records as a cluster. Not supported in VIs that run in a web application session in Handle ...