Adds one measurement to the list of processing steps that are completed before the measurement. Not supported Not supported in VIs that run in a web application Processing Measurements The processing is ...

For the PXI-5900 PXI RF Amplifier, this node calibrates the gain and offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize ...

For NI 5105 digitizers, this function calibrates the external clock digital clock managers (DCMs). DCM calibration ensures that data can be sampled at the correct time in the clock period. Not supported ...

For the PXIe-5622, this node calibrates the frequency response of the device. This node is called multiple times, once for each frequency point in the sweep. You must supply the stimulus frequency, in ...

Externally calibrates the vertical range for the specified channel and vertical range setting. Not supported Not supported in VIs that run in a web application session in The instrument handle that you ...

Clears the list of processing steps assigned to the given channel. Not supported Not supported in VIs that run in a web application Processing StepsThe processing steps are added with Add Waveform Processing, ...

Ends an niScope instrument I/O session and performs closing actions. This function performs the following actions: Closes the instrument I/O session. Destroys the IVI session and all of its properties ...

Commits to hardware all the parameter settings associated with the task. Use this function if you want a parameter change to be immediately reflected in the hardware. This node is not supported by Traditional ...

Use the NI-SCOPE Configuration functions to set up the parameters of your acquisition, or use Auto Setup to automatically configure device settings.

Configures how the digitizer acquires data and fills the waveform record. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session ...

Retrieves the waveform the digitizer has acquired for multiple channels and records. This function returns a one-dimensional array of complex, scaled waveforms in clusters that include timing information. ...

Retrieves the waveform the digitizer has acquired for multiple channels and records. This function returns scaled voltage waveforms in a cluster that includes timing information. Not supported Not supported ...

Retrieves complex waveforms the digitizer has acquired from multiple records or multiple channels. This function returns a one-dimensional array of complex waveform data types (WDT) that includes timing ...

Retrieves waveforms the digitizer has acquired from multiple records or multiple channels. This function returns a one-dimensional array of waveform data types that include timing information. Not supported ...

Retrieves data from multiple channels and records. This function returns a two-dimensional array of complex, scaled waveforms. Not supported Not supported in VIs that run in a web application session in ...

Retrieves data from multiple records or multiple channels. This function returns a two-dimensional array of scaled voltage waveforms. Not supported Not supported in VIs that run in a web application session ...

Retrieves data from multiple channels and records. This function returns a two-dimensional array of binary 16-bit waveforms. Not supported Not supported in VIs that run in a web application session in ...

Retrieves data from multiple channels and records. This function returns a two-dimensional array of binary 32-bit waveforms. Not supported Not supported in VIs that run in a web application session in ...

Retrieves data from multiple channels and records. This function returns a two-dimensional array of binary 8-bit waveforms. Not supported Not supported in VIs that run in a web application session in Handle ...

Retrieves data from single channels and records. This function returns a one-dimensional array of complex, scaled waveforms. Not supported Not supported in VIs that run in a web application session in ...

Configures the most commonly configured properties of the digitizer vertical subsystem, such as the range, offset, coupling, probe attenuation, and the channel name. Some features are not supported by ...

Aborts the current task, opens the data channel relays, and releases all RTSI and PFI lines. Use this function for a condition where you want to stop the current acquisition and disable the channels. Not ...

Retrieves data from a single channel and record. Returns a one-dimensional array of binary 8-bit values. Not supported Not supported in VIs that run in a web application session in Handle that identifies ...

Retrieves complex waveforms the digitizer has acquired for the specified channel. This function returns a one-dimensional array of data that includes timing information. Not supported Not supported in ...

Obtains multiple waveforms from the digitizer and returns the specified array measurement for multiple channels and records as a cluster. Not supported in VIs that run in a web application session in Handle ...

Returns the sample mode the digitizer is currently using. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously ...

Obtains a waveform from the digitizer and returns the specified measurement array for a single channel and record as a cluster along with timing data. Not supported Not supported in VIs that run in a web ...