Adds one measurement to the list of processing steps that are completed before the measurement. Not supported Not supported in VIs that run in a web application Processing Measurements The processing is ...

For the PXI-5900 PXI RF Amplifier, this node calibrates the gain and offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize ...

Externally calibrates the compensation attenuator. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External Calibration. ...

For NI 5105 digitizers, this function calibrates the external clock digital clock managers (DCMs). DCM calibration ensures that data can be sampled at the correct time in the clock period. Not supported ...

For the PXIe-5622, this node calibrates the frequency response of the device. This node is called multiple times, once for each frequency point in the sweep. You must supply the stimulus frequency, in ...

Returns a writer endpoint that can be used with NI-P2P to configure a peer-to-peer stream with a digitizer endpoint. Not supported Not supported in VIs that run in a web application session in Handle that ...

Externally calibrates the vertical range for the specified channel and vertical range setting. Not supported Not supported in VIs that run in a web application session in The instrument handle that you ...

Returns coefficients that can be used to scale binary data to volts. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External ...

Calibrates the sample rate of SMC-based digitizers. Use this node only when following the external calibration procedure for your device. This node adjusts the frequency of the voltage controlled crystal ...

Changes the password used to begin an external calibration session. This node verifies old password against the password stored in the device's EEPROM. If the two passwords match, the node stores the new ...

Clears the waveform statistics on the channel and measurement you specify. Clears the statistical information and the multi-acquisition array measurements. Every time a measurement is called, the statistics ...

Clears the list of processing steps assigned to the given channel. Not supported Not supported in VIs that run in a web application Processing StepsThe processing steps are added with Add Waveform Processing, ...

Ends an niScope instrument I/O session and performs closing actions. This function performs the following actions: Closes the instrument I/O session. Destroys the IVI session and all of its properties ...

Commits to hardware all the parameter settings associated with the task. Use this function if you want a parameter change to be immediately reflected in the hardware. This node is not supported by Traditional ...

Use the NI-SCOPE Configuration functions to set up the parameters of your acquisition, or use Auto Setup to automatically configure device settings.

Sets, gets, or checks properties relating to NI-SCOPE. Not supported Not supported in VIs that run in a web application niscope in Identifies a particular NI-SCOPE instrument session. error in Error conditions ...

Configures the properties that control the electrical characteristics of the channel. This function configures the input impedance and the bandwidth. Not supported Not supported in VIs that run in a web ...

Configures the properties for synchronizing the digitizer to an external clock or sending the digitizer's clock output to be used as a synchronizing clock for other devices. Not supported Not supported ...

Configures the custom coefficients for the equalization finite impulse response (FIR) filter on the device. The FIR filter is designed to compensate the input signal for artifacts introduced to the signal ...

Configures the common properties of the horizontal subsystem for a single record or multi-record acquisition. Not supported Not supported in VIs that run in a web application enforce realtime A Boolean ...

Configures common properties for edge triggering. When you initiate an acquisition, the digitizer waits for the start trigger, which is configured through the Trigger Source property. The default is immediate. ...

Configures common properties for hysteresis triggering. This kind of trigger specifies an additional value in the hysteresis parameter, that a signal must pass through before a trigger can occur. This ...

Configures the common properties specific to video triggering. Not supported Not supported in VIs that run in a web application Using Trigger Holdoff for Video TriggeringUse trigger holdoff to skip a specific ...

Configures common properties for window triggering. A window trigger occurs when a signal enters or leaves a window you specify with high level or low level. Not supported Not supported in VIs that run ...

Configures the common properties of a digital trigger. Not supported Not supported in VIs that run in a web application trigger slope The trigger edge on which to trigger the digitizer. session in Handle ...

Initiates an acquisition, waits for it to complete, and performs the specified waveform measurement for multiple channels and records. Not supported Not supported in VIs that run in a web application session ...

Configures the most commonly configured properties of the digitizer vertical subsystem, such as the range, offset, coupling, probe attenuation, and the channel name. Some features are not supported by ...

Returns the waveform the digitizer acquires for the specified channel. This function initiates an acquisition that returns a scaled voltage waveform in a waveform data type that includes timing information. ...

Takes the error code returned by NI-SCOPE functions and returns the interpretation as a user-readable string. You can pass VI_NULL as the instrument handle, which is useful to interpret errors if Initialize ...