For the PXI-5900 PXI RF Amplifier, this node calibrates the gain and offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize ...

Externally calibrates the compensation attenuator. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External Calibration. ...

Externally calibrates the vertical offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize External Calibration. The handle ...

Externally calibrates the vertical range for the specified channel and vertical range setting. Not supported Not supported in VIs that run in a web application session in The instrument handle that you ...

Configures the relative sample clock delay, in seconds, when using the internal clock. Each time this node is called, the Sample clock is delayed from the Reference clock by the specified amount of time. ...

Calibrates the sample rate of SMC-based digitizers. Use this node only when following the external calibration procedure for your device. This node adjusts the frequency of the voltage controlled crystal ...

Automatically configures the digitizer. When you call this node, the digitizer senses the input signal and automatically configures many of the instrument settings. If a signal is detected on a channel, ...

Changes the password used to begin an external calibration session. This node verifies old password against the password stored in the device's EEPROM. If the two passwords match, the node stores the new ...

Clears the waveform statistics on the channel and measurement you specify. Clears the statistical information and the multi-acquisition array measurements. Every time a measurement is called, the statistics ...

Clears the list of processing steps assigned to the given channel. Not supported Not supported in VIs that run in a web application Processing StepsThe processing steps are added with Add Waveform Processing, ...

Ends an niScope instrument I/O session and performs closing actions. This function performs the following actions: Closes the instrument I/O session. Destroys the IVI session and all of its properties ...

Commits to hardware all the parameter settings associated with the task. Use this function if you want a parameter change to be immediately reflected in the hardware. This node is not supported by Traditional ...

Use the NI-SCOPE Configuration functions to set up the parameters of your acquisition, or use Auto Setup to automatically configure device settings.

Configures how the digitizer acquires data and fills the waveform record. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session ...

Configures the custom coefficients for the equalization finite impulse response (FIR) filter on the device. The FIR filter is designed to compensate the input signal for artifacts introduced to the signal ...

Configures common properties for window triggering. A window trigger occurs when a signal enters or leaves a window you specify with high level or low level. Not supported Not supported in VIs that run ...

Configures the common properties of a digital trigger. Not supported Not supported in VIs that run in a web application trigger slope The trigger edge on which to trigger the digitizer. session in Handle ...

Configures common properties for immediate triggering. Immediate triggering means the digitizer triggers itself. Not supported Not supported in VIs that run in a web application session in Handle that ...

Configures common properties for software triggering. Not supported Not supported in VIs that run in a web application session in Handle that identifies the NI-SCOPE instrument session as previously allocated ...

Configures the most commonly configured properties of the digitizer vertical subsystem, such as the range, offset, coupling, probe attenuation, and the channel name. Some features are not supported by ...

Aborts the current task, opens the data channel relays, and releases all RTSI and PFI lines. Use this function for a condition where you want to stop the current acquisition and disable the channels. Not ...

Takes the error code returned by NI-SCOPE functions and returns the interpretation as a user-readable string. You can pass VI_NULL as the instrument handle, which is useful to interpret errors if Initialize ...

Configures the digitizer to generate a signal that other devices can detect when configured for digital triggering or sharing clocks. Not supported Not supported in VIs that run in a web application Using ...

Obtains multiple waveforms from the digitizer and returns the specified array measurement for multiple channels and records as a cluster. Not supported in VIs that run in a web application session in Handle ...

Obtains a waveform from the digitizer and returns the specified measurement voltage data. This instance can fetch data from multiple channels and records. Not supported Not supported in VIs that run in ...

Obtains a waveform from the digitizer and returns the specified measurement voltage data for a single channel and record. Not supported Not supported in VIs that run in a web application session in Handle ...

Obtains a waveform from the digitizer and returns the specified measurement array for a single channel and record as a cluster along with timing data. Not supported Not supported in VIs that run in a web ...