Filtered Results

Sets the output mode of the waveform generator, which determines how the waveform generator produces waveforms. The waveform generator must not be in the Generating state when you call this node. Not supported ...

Configures the Start Trigger to detect peer-to-peer endpoint fullness. Generation begins when the number of samples in the peer-to-peer endpoint reaches the threshold indicated by the fullness level. Because ...

Sets the waveform generator Reference Clock source and frequency. The waveform generator uses the Reference Clock to tune the Sample Clock Timebase of the waveform generator so that the frequency stability ...

Configures a Script Trigger for software triggering. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application ...

Configures the Start Trigger for software triggering. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application ...

Configures the waveform, amplitude, DC offset, frequency, and start phase standard waveform properties of the waveform generator. Not supported Not supported in VIs that run in a web application You must ...

Sets the trigger mode for your waveform generator. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application niFgen ...

Sets the trigger source. The waveform generator responds to a trigger according to the current trigger mode.

Creates an arbitrary sequence from an array of waveform references and an array of corresponding loop counts with the ability to set the number of samples in each sequence step and to set marker locations. ...

Aborts any previously initiated waveform generation. Not supported Not supported in VIs that run in a web application niFgen Abort Generation.vi :/nifgenlv.chm::/niFgen_Abort_Generation.html session ...

Use the NI-FGEN ADC control nodes only when following the calibration procedure of the waveform generator.

Calculates calibration constants pertaining to the gain and offset of the onboard calibration ADC. During external calibration, you can generate voltages and measure them both externally and with the calibration ...

Creates an onboard waveform from complex waveform data type (WDT) data for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must not be in the Generating state when ...

Calculates calibration constants pertaining to direct analog path output impedance. During external calibration, you can put the waveform generator in different configurations and take measurements of ...

Creates an onboard waveform from I16 data for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must not be in the Generating state when you call this node. Not supported ...

Creates an onboard waveform from waveform data type (WDT) data for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must not be in the Generating state when you call ...

Calculates calibration constants pertaining to the postamplifier gain and offset of the main analog path. During external calibration, you can put the waveform generator in different configurations; program ...

Calculates calibration constants pertaining to the preamplifier gain of the main analog path. During external calibration, you can put the waveform generator in different configurations; program different ...

Calculates calibration constants pertaining to the preamplifier gain of the main analog path. During external calibration, you can put the waveform generator in different configurations; program different ...

Calculates calibration constants pertaining to the oscillator. During external calibration, you can generate sine waves and take measurements of the resulting output frequencies. Using the desired and ...

Delays (or phase shifts) the Sample Clock, which delays the output of the waveform generator. The delay takes effect immediately after this node is called. Delaying the Sample Clock can be useful when ...

Specifies the initial size of a named waveform so that it can be allocated in onboard memory before loading the associated data. Not supported Not supported in VIs that run in a web application After this ...

Disables the Script Trigger. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application niFgen Disable Script Trigger.vi ...

Use the NI-FGEN analog output nodes only when following the calibration DC gain and offset portion of the waveform generator calibration procedure.

Use the NI-FGEN arbitrary waveform nodes to configure, define, and clear an arbitrary waveform.

Use the NI-FGEN arbitrary sequence waveform nodes to configure, define, and clear an arbitrary sequence.

Converts a status code returned by an NI-FGEN node into a user-readable string. Not supported Not supported in VIs that run in a web application niFgen Error Message.vi :/nifgenlv.chm::/niFgen_Error_Message.html ...

Changes the password that is required to initialize an external calibration session. Not supported Not supported in VIs that run in a web application niFgen Change Ext Cal Password.vi :/nifgenlv.chm::/niFgen_Change_Ext_Cal_Password.html ...

Use the NI-FGEN external calibration nodes to perform external calibration when following the calibration procedure for your waveform generator model.

Showing 1-30 of 141 results