Filtered Results

When you install NI-FGEN on a 64-bit system, you can monitor, control, and record measurements from supported devices using InstrumentStudio. InstrumentStudio is a software-based front panel application ...

Writes a 16-bit value to the DAC, which could be output as a DC voltage. This node writes to the DAC only when used in an external calibration session. Not supported Not supported in VIs that run in a ...

Writes complex data to the named waveform in onboard memory when the OSP Enabled property is set to True and the Data Processing Mode property is set to Complex. If streaming is enabled, you can write ...

Writes complex waveform data type (WDT) data to the named waveform in onboard memory when the OSP Enabled property is set to True and the Data Processing Mode property is set to Complex. If streaming is ...

Writes floating-point data to the named waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to this node ...

Writes a specified amount of data from a Direct DMA-compatible waveform generator to the named waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size ...

Writes binary data to the named waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to this node continues ...

Writes waveform data type (WDT) data to the named waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to ...

Writes a string containing one or more scripts that govern the generation of waveforms. Not supported Not supported in VIs that run in a web application niFgen Write Script.vi :/nifgenlv.chm::/niFgen_Write_Script.html ...

Writes complex data to a waveform in onboard memory when the OSP Enabled property is set to True and the Data Processing Mode property is set to Complex. If streaming is enabled, you can write more data ...

Writes floating-point data to a waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to this node continues ...

Writes complex waveform data type (WDT) data to a waveform in onboard memory when the OSP Enabled property is set to True and the Data Processing Mode property is set to Complex. If streaming is enabled, ...

Writes a specified amount of data from a Direct DMA-compatible waveform generator to the waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in ...

Writes binary data to a waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to this node continues writing ...

Writes waveform data type (WDT) data to the waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to this node ...

Takes waveform data from a specified Hierarchical Waveform Storage (HWS) file and creates an onboard waveform for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must ...

Takes binary data from a specified file of 16-bit integers and creates an onboard waveform for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must not be in the Generating ...

Takes the data provided and creates an onboard waveform of the same size for use in arbitrary waveform or arbitrary sequence output modes.

Defines a user waveform for either standard function or frequency list output mode. Not supported Not supported in VIs that run in a web application You must set the output mode input of Configure Output ...

Deletes the specified named waveform from onboard memory. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application ...

Deletes the specified script from onboard memory. Not supported Not supported in VIs that run in a web application niFgen Delete Script.vi :/nifgenlv.chm::/niFgen_Delete_Script.html session in ...

Disables the Script Trigger. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application niFgen Disable Script Trigger.vi ...

Disables the Start Trigger. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application niFgen Disable Start Trigger.vi ...

Disables the analog output and all exported signals. Places the instrument in a quiescent state in which it has minimal or no impact on the system to which it is connected. Not supported Not supported ...

Converts a status code returned by an NI-FGEN node into a user-readable string. Not supported Not supported in VIs that run in a web application niFgen Error Message.vi :/nifgenlv.chm::/niFgen_Error_Message.html ...

Routes signals (clocks, triggers, and events) to the output terminal you specify. Any routes created within a session persist after the session closes to prevent signal glitching. Not supported Not supported ...

Use the NI-FGEN external calibration nodes to perform external calibration when following the calibration procedure for your waveform generator model.

Use the NI-FGEN external calibration utility nodes to get information about previous calibrations, store information, or password protect the external calibration data on your board.

Showing 1-30 of 141 results
1 of 5 pages