Filtered Results

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A DAQmx property node preselected to contain System class properties. You can select other classes from the node on the diagram.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Indicates the coupling types supported by this device. Not supported Not supported in VIs that run in a web application AC 10045 Remove the DC offset from the signal. DC 10050 Allow NI-DAQmx to measure ...

Indicates the set of discrete internal current excitation values supported by this device. Not supported Not supported in VIs that run in a web application 29CB attr29CB.html

Indicates the pairs of current input ranges supported by this device. Each pair consists of the low value, followed by the high value. Not supported Not supported in VIs that run in a web application 2991 ...

Indicates the set of discrete lowpass cutoff frequencies supported by this device. If the device supports ranges of lowpass cutoff frequencies, use AI.DigFltr.Lowpass.CutoffFreq.RangeVals to determine ...

Indicates pairs of lowpass cutoff frequency ranges supported by this device. Each pair consists of the low value, followed by the high value. If the device supports a set of discrete lowpass cutoff frequencies, ...

Use the DAQmx TEDS nodes to configure physical channels to use and to retrieve TEDS information from a physical channel.

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires current excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

Indicates the input gain settings supported by this device. Not supported Not supported in VIs that run in a web application 2993 attr2993.html

Indicates the set of discrete lowpass cutoff frequencies supported by this device. If the device supports ranges of lowpass cutoff frequencies, use AI.Lowpass.CutoffFreq.RangeVals to determine supported ...

Indicates the maximum sampling rate for an analog input task from this device. To find the maximum rate for the task, take the minimum of AI.MaxSingleChanRate or the indicated sampling rate of this device ...

Indicates the maximum rate for an analog input task if the task contains only a single channel from this device. Not supported Not supported in VIs that run in a web application 298C attr298C.html

Indicates the measurement types supported by the physical channels of the device. Refer to AI.MeasTypes for information on specific channels. Not supported Not supported in VIs that run in a web application ...

Indicates the minimum rate for an analog input task on this device. NI-DAQmx returns a warning or error if you attempt to sample at a slower rate. Not supported Not supported in VIs that run in a web application ...

Indicates the number of Analog Input sample timing engines supported by the device. Not supported Not supported in VIs that run in a web application 692 attr692.html

Indicates the number of Analog Input synchronization pulse sources supported by the device. Not supported Not supported in VIs that run in a web application 692 attr692.html

Sets the source of the Sample Clock, the rate of the Sample Clock, and the number of samples to acquire or generate. The device acquires or generates samples on each Sample Clock edge, but it does not ...

Indicates pairs of input resistance ranges, in ohms, supported by devices that have the necessary signal conditioning to measure resistances. Each pair consists of the low value followed by the high value. ...

Indicates sample modes supported by devices that support sample clocked analog input. Not supported Not supported in VIs that run in a web application Finite Samples 10178 Acquire or generate a finite ...

Indicates if the device supports simultaneous sampling. Not supported Not supported in VIs that run in a web application 298F attr298F.html

Indicates the triggers supported by this device for an analog input task. Not supported Not supported in VIs that run in a web application Advance 12488 Advance trigger. Pause 12489 Pause trigger. Reference ...

Indicates the set of discrete internal voltage excitation values supported by this device. If the device supports ranges of internal excitation values, use AI.Voltage.IntExcit.RangeVals to determine supported ...

Indicates pairs of input voltage ranges supported by this device. Each pair consists of the low value, followed by the high value. Not supported Not supported in VIs that run in a web application 2990 ...

Showing 1-30 of 1955 results
1 of 66 pages