Filtered Results

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Adjusts the external calibration constants for the analog input section of a DSA device. You must connect a known voltage to the device and specify that voltage with reference voltage. LabVIEW NXG does ...

Adjusts the external calibration constants for the analog output section of a DSA device. You must use the device to generate a high voltage and low voltage at a specified gain, measure the high and low ...

Adjusts the external calibration constants for the timebase of a DSA device with an adjustable oscillator. You must first call the DAQmx Setup DSA AO Timebase Calibration node and measure the frequency ...

Returns the reference current values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9228 Calibration ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Computes a set of coefficients for a polynomial that approximates the inverse of the polynomial with the coefficients you specify with the coefficients input. This VI generates a table of x versus y values ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Associates TEDS information with the physical channel you specify. If you do not specify the filename of a data sheet in the virtual TEDS file input, this node attempts to find a TEDS sensor connected ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Configures a connection on the SC Express accessory for the specified physical channel(s). LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Connect SC ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

The DAQmx I/OConstants & Property Nodes palette contains all I/O constants and Property Nodes you can use in NI-DAQmx.

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Controls the watchdog timer task according to the action you specify. This node does not program the watchdog timer on a real-time controller. Use the Real-Time Watchdog to program the watchdog timer on ...

Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9251 Calibration ...

Adjusts the external calibration constants for an SCXI-1141 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 1141 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Returns the reference voltage values to be measured by a reference device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9263 Calibration Adjustment ...

Adjusts the external calibration constants for an SCXI-1143 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 1143 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an SCXI-1502 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 1502 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI PXIe-4330 or NI PXIe-4331 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 433x Calibration.vi ...

Adjusts the external calibration constants for an NI PXIe-4353 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 4353 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) to measure resistance. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Adjusts the external calibration constants for an SCXI-1521 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 1521 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Showing 1-30 of 1900 results
1 of 64 pages