Filtered Results

Before proceeding, verify that the PXIe-4147 appears in MAX. If the ACCESS LED fails to light after you power on the chassis, a problem may exist with the chassis power rails, a hardware module, or the ...

Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX informs other programs about which NI hardware products are in the system and how they are configured. MAX is automatically ...

In the MAX configuration tree, expand Devices and Interfaces . Expand the Chassis tree to see the list of installed hardware, and press to refresh the list. If the module is still not listed, power ...

Notice To prevent damage to the PXIe-4147 caused by ESD or contamination, handle the module using the edges or the metal bracket. Ensure the AC power source is connected to the chassis before installing ...

You must be an Administrator to install NI software on your computer. Install an ADE, such as LabVIEW or LabWindows™/CVI™. Download the driver software installer from ni.com/downloads or install the driver ...

This document explains how to install, configure, and test the PXIe-4147 . The PXIe-4147 ships with NI-DCPower driver software, which you can use to program the module. Note Before you begin, install and ...

Restart the system. Launch MAX. Failed self-test Perform self-calibration, then perform the self-test again. The PXIe-4147 must be calibrated to pass the self-test. Failed self-calibration Perform self-calibration ...

There are several required items not included in your PXIe-4147 kit that you need to operate the PXIe-4147. Your application may require additional items not included in your kit to install or operate ...

A B PXIe- 4147 4-CH Precision SMU ALL CHANNEL SIGNALS ±8 V , 3 A MAX 60V MAX to OUTPUT 0 1 2 3 GUARD LO S LO GUARD HI S HI ACCESS VOLTAGE 1 2 3 4 5 6

You can generate signals interactively using InstrumentStudio or you can use the NI-DCPower instrument driver to program your device in the supported ADE of your choice.

Self-calibration adjusts the PXIe-4147 for variations in the module environment. Perform a complete self-calibration after the first time you install the PXIe-4147.

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support.

Notice To prevent electrostatic discharge (ESD) from damaging the module, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. Touch the antistatic package ...

custom applications with an application programming interface (API). InstrumentStudio NI-DCPower Instrument Driver about hardware features or review device specifications. more about your products through ...

Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Characteristics describe values that are relevant to the ...

You can manipulate the aperture time of measurements made with NI-DCPower instruments to reject specific AC noise frequencies in DC voltage and current measurements.

This documentation contains information on the PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, PXIe-4139, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145.

Figure 1. PXIe-4147 Block Diagram Power Stage Shunts Isolators SourceAdapt FPGA SourceAdapt Measurement Unit References Measurement Unit PXI Express Backplane DB25 Male Channel 0 60 V CAT I Isolation 60 ...

The Power Allocation properties allow you to control when errors are generated in situations that could cause an instrument channel to source more power than is possible on that channel or on the entire ...

A B PXIe- 4147 4-CH Precision SMU ALL CHANNEL SIGNALS ±8 V , 3 A MAX 60V MAX to OUTPUT 0 1 2 3 GUARD LO S LO GUARD HI S HI ACCESS VOLTAGE 1 2 3 4 5 6

This instrument supports SourceAdapt custom transient response, which allows you to set compensation parameters to fine-tune the transient response of a channel for your specific application.

The measurement range is implicitly selected based on the configured output range. You cannot change the measurement range independently of the output range. The selected measurement range is large enough ...

The PXIe-4147 includes a self-calibration feature that you can use to significantly reduce many error sources, such as voltage source and measure offset error, voltage source and measure gain error, and ...

You can use the PXI Express trigger bus to send and receive events and triggers. You can characterize signal routing operations by source and destination. The possible signal routes depend on the instrument, ...

NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment ...

Your kit includes an assembled TB-414X. In addition, you will need the following items not included in your TB-414X kit to install and use the TB-414X.