This document describes the range of software versions required for the aforementioned devices and links to the most recent documentation resources available at ni.com/manuals for each device. Note: Your ...
CALIBRATION PROCEDURE NI 9210 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module This document contains the verification and adjustment procedures for the NI 9210. For more information ...
This guide describes how to select a C Series cable or accessory that is compatible with your C Series Module. National Instruments provides over a hundred different C Series I/O models. This guide includes ...
NI is discontinuing several legacy product lines on September 28th, 2018. We understand that this is a large change to the overall product portfolio. In order to ease the difficultly of this change we ...
This tutorial lists the C Series modules for the CompactDAQ product line and the CompactRIO product line. It does not include compatibility for CompactRIO Single Board (sbRIO) Controllers. For a list of ...
Use this guide to match your C Series Modules with Mini-TC front connection with a compatible cable and accessory to meet the needs of your application, whether you are creating a new configuration, replacing ...
Glossary NI CompactRIO Device Drivers Help Edition Date: December 2017 Part Number: 373197L-01 »View Product Info Download Help (Windows Only) Clear view of the sky There is no strict ...
Calibrating the NI 9210 requires the installation of NI-DAQmx 16.1 or later on the calibration system. You can download NI-DAQmx from https://NI.COM/DOWNLOADS . NI-DAQmx supports LabVIEW, LabWindows™/CVI™, ...
Complete the following procedure to adjust the accuracy performance of the NI 9210. Set the calibrator to Standby mode (STBY). Connect the NI 9210 to the calibrator as shown in Figure 1. Set the calibrator ...
Complete the following procedure to determine the As-Found status of the NI 9210. Set the calibrator to Standby mode (STBY). Connect the NI 9210 to the calibrator as shown in Figure 1. Figure 1. Accuracy ...
Consult the following documents for information about the NI 9210, NI-DAQmx, and your application software. All documents are available on https://NI.COM and help files install with the software. NI cDAQ-9174/9178 ...
Complete the following steps to set up the NI 9210. Install NI-DAQmx. Make sure the cDAQ-9178 power source is not connected. Connect the cDAQ-9178 to the system ground. Attach a ring lug to a 14 AWG (1.6 ...
Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...
The following performance adjustment procedure describes the sequence of operation required to adjust the NI 9210. Parent topic: NI 9210 Calibration Procedure
When an adjustment procedure is completed, the NI 9210 internal calibration memory (EEPROM) is immediately updated. If you do not want to perform an adjustment, you can update the calibration date and ...
This document contains the verification and adjustment procedures for the NI 9210. For more information about calibration solutions, visit https://NI.COM/CALIBRATION .
Repeat the Verification section to determine the As-Left status of the device. Note If any test fails Re-Verification after performing an adjustment, verify that you have met the Test Conditions before ...
The following setup and environmental conditions are required to ensure the NI 9210 meets published specifications. Keep connections to the NI 9210 as short as possible. Long cables and wires act as antennae, ...
Table 1 lists the equipment recommended for the performance verification and adjustment procedures. If the recommended equipment is not available, select a substitute using the requirements listed in Table ...
The following performance verification procedure describes the sequence of operation and test points required to verify the NI 9210 and assumes that adequate traceable uncertainties are available for the ...