Creates and returns a new NI-FGEN session to the specified channel of a waveform generator that is used in all subsequent NI-FGEN calls. Optionally sets the initial state of session properties Range Check, ...

Sets the output mode of the waveform generator, which determines how the waveform generator produces waveforms. The waveform generator must not be in the Generating state when you call this node. Not supported ...

Takes the data provided and creates an onboard waveform of the same size for use in arbitrary waveform or arbitrary sequence output modes.

Calculates calibration constants pertaining to main analog path output impedance. During external calibration, you can put the waveform generator in different configurations and take measurements of the ...

Specifies the size of a waveform so that it can be allocated in onboard memory before loading the associated data. The waveform generator must not be in the Generating state when you call this node. Not ...

Changes the password that is required to initialize an external calibration session. Not supported Not supported in VIs that run in a web application niFgen Change Ext Cal Password.vi :/nifgenlv.chm::/niFgen_Change_Ext_Cal_Password.html ...

Closes an external calibration session and, if specified, stores the new calibration constants and calibration data, such as time and temperature, in the onboard EEPROM. Not supported Not supported in ...

Configures the state of the DIGITAL DATA & CONTROL/DIGITAL PATTERN connector. Not supported Not supported in VIs that run in a web application niFgen Configure Digital Patterning.vi :/nifgenlv.chm::/niFgen_Configure_Digital_Patterning.html ...

Configures the properties of the waveform generator that affect frequency list generation, selecting the frequency list to produce and setting the amplitude, DC offset, and start phase. The waveform generator ...

Sets the output mode of the waveform generator, which determines how the waveform generator produces waveforms. The waveform generator must not be in the Generating state when you call this node. Not supported ...

Configures the Start Trigger to detect peer-to-peer endpoint fullness. Generation begins when the number of samples in the peer-to-peer endpoint reaches the threshold indicated by the fullness level. Because ...

Sets the source of the Sample Clock of the waveform generator. Not supported Not supported in VIs that run in a web application niFgen Configure Sample Clock Source.vi :/nifgenlv.chm::/niFgen_Configure_Sample_Clock_Source.html ...

Configures the Start Trigger for software triggering. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application ...

Configures the waveform, amplitude, DC offset, frequency, and start phase standard waveform properties of the waveform generator. Not supported Not supported in VIs that run in a web application You must ...

Sets the trigger mode for your waveform generator. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application niFgen ...

Creates a frequency list from an array of frequencies and an array of durations. The waveform generator generates each frequency for the given amount of time and then moves on to the next frequency. When ...

Creates an onboard waveform from complex double-precision floating-point data for use in arbitrary waveform or arbitrary sequence output modes on waveform generators with the OSP Enabled property set to ...

Creates an onboard waveform from I16 data for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must not be in the Generating state when you call this node. Not supported ...

Takes waveform data from a specified file of double-precision floating-point data and creates an onboard waveform for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator ...

Disables the Start Trigger. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application niFgen Disable Start Trigger.vi ...

Returns the FIR filter coefficients used by the onboard signal processing block. Not supported Not supported in VIs that run in a web application This node is supported only for the PXI-5441. niFgen Get ...

Returns the date and time of the last successful external calibration. Not supported Not supported in VIs that run in a web application niFgen Get Ext Cal Last Date And Time.vi :/nifgenlv.chm::/niFgen_Get_Ext_Cal_Last_Date_and_Time.html ...

Returns the date and time of the last successful self-calibration. Not supported Not supported in VIs that run in a web application niFgen Get Self Cal Last Date And Time.vi :/nifgenlv.chm::/niFgen_Get_Self_Cal_Last_Date_and_Time.html ...

Configures the waveform generator to begin flatness calibration. Not supported Not supported in VIs that run in a web application niFgen Initialize Flatness Calibration.vi :/nifgenlv.chm::/niFgen_Initialize_Flatness_Calibration.html ...

Returns the properties of the waveform generator that are related to creating arbitrary waveforms. Not supported Not supported in VIs that run in a web application niFgen Query Arb Waveform Capabilities.vi ...

Writes binary data to the named waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to this node continues ...

Writes waveform data type (WDT) data to the named waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to ...

Writes complex waveform data type (WDT) data to a waveform in onboard memory when the OSP Enabled property is set to True and the Data Processing Mode property is set to Complex. If streaming is enabled, ...

Calculates calibration constants pertaining to the gain of the direct analog path. During external calibration, you can put the waveform generator in different configurations; program different gain and ...

Calculates calibration constants pertaining to the oscillator. During external calibration, you can generate sine waves and take measurements of the resulting output frequencies. Using the desired and ...