Calculates calibration constants pertaining to flatness. During external calibration, the waveform generator is configured with the different analog settings, and measurements are taken of the resulting ...

Calculates calibration constants pertaining to the preamplifier gain of the main analog path. During external calibration, you can put the waveform generator in different configurations; program different ...

Calculates calibration constants pertaining to the preamplifier gain of the main analog path. During external calibration, you can put the waveform generator in different configurations; program different ...

Use the NI-FGEN configuration nodes to configure and control the analog and digital output, clocking, triggering, onboard signal processing, and generation of standard functions, arbitrary waveforms, arbitrary ...

Creates a frequency list from an array of frequencies and an array of durations. The waveform generator generates each frequency for the given amount of time and then moves on to the next frequency. When ...

Creates an onboard waveform from complex double-precision floating-point data for use in arbitrary waveform or arbitrary sequence output modes on waveform generators with the OSP Enabled property set to ...

Takes waveform data from a specified file of double-precision floating-point data and creates an onboard waveform for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator ...

Routes signals (clocks, triggers, and events) to the output terminal you specify. Any routes created within a session persist after the session closes to prevent signal glitching. Not supported Not supported ...

Creates and returns a new NI-FGEN session to the specified channel of a waveform generator that is used in all subsequent NI-FGEN calls. Optionally sets the initial state of session properties Range Check, ...

Writes complex data to the named waveform in onboard memory when the OSP Enabled property is set to True and the Data Processing Mode property is set to Complex. If streaming is enabled, you can write ...

Writes waveform data type (WDT) data to the named waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to ...

Writes a specified amount of data from a Direct DMA-compatible waveform generator to the waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in ...

Returns the date and time of the last successful external calibration. Not supported Not supported in VIs that run in a web application niFgen Get Ext Cal Last Date And Time.vi :/nifgenlv.chm::/niFgen_Get_Ext_Cal_Last_Date_and_Time.html ...

Stores user-defined information in the onboard EEPROM. Not supported Not supported in VIs that run in a web application niFgen Set Cal User Defined Info.vi :/nifgenlv.chm::/niFgen_Set_Cal_User_Defined_Info.html ...

Removes a previously created arbitrary sequence from the waveform generator memory and invalidates the handle of the specified arbitrary sequence. The waveform generator must not be in the Generating state ...

Removes a previously created arbitrary waveform from the waveform generator memory and invalidates the reference of the specified arbitrary waveform. The waveform generator must not be in the Generating ...

Removes a previously created frequency list from the waveform generator memory and invalidates the handle of the specified frequency list. The waveform generator must not be in the Generating state when ...

Removes a previously created user-defined waveform created by Define User Standard Waveform from the waveform generator memory and invalidates the handle of the specified frequency list. Not supported ...

Closes an external calibration session and, if specified, stores the new calibration constants and calibration data, such as time and temperature, in the onboard EEPROM. Not supported Not supported in ...

Closes the instrument I/O session, destroys the NI-FGEN session and all of its properties, and deallocates any memory resources NI-FGEN uses. Not supported Not supported in VIs that run in a web application ...

Configures the waveform generator properties that affect arbitrary sequence generation, selecting the arbitrary sequence to produce and setting the gain and offset. The waveform generator must not be in ...

Selects the clock mode for the waveform generator. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported in VIs that run in a web application You ...

Configures the Start Trigger for edge triggering, setting the trigger source and edge to detect. The waveform generator must not be in the Generating state when you call this node. Not supported Not supported ...

Configures the Start Trigger to detect peer-to-peer endpoint fullness. Generation begins when the number of samples in the peer-to-peer endpoint reaches the threshold indicated by the fullness level. Because ...

Creates an arbitrary sequence from an array of waveform references and an array of corresponding loop counts. The waveform generator must not be in the Generating state when you call this node. Not supported ...

When you install NI-FGEN on a 64-bit system, you can monitor, control, and record measurements from supported devices using InstrumentStudio. InstrumentStudio is a software-based front panel application ...

Aborts any previously initiated waveform generation. Not supported Not supported in VIs that run in a web application niFgen Abort Generation.vi :/nifgenlv.chm::/niFgen_Abort_Generation.html session ...

Creates an onboard waveform from I16 data for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must not be in the Generating state when you call this node. Not supported ...

Use the NI-FGEN ADC control nodes only when following the calibration procedure of the waveform generator.

Calculates calibration constants pertaining to the gain and offset of the onboard calibration ADC. During external calibration, you can generate voltages and measure them both externally and with the calibration ...