Writes complex data to the named waveform in onboard memory when the OSP Enabled property is set to True and the Data Processing Mode property is set to Complex. If streaming is enabled, you can write ...

Writes floating-point data to a waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in onboard memory. By default, a call to this node continues ...

Writes a specified amount of data from a Direct DMA-compatible waveform generator to the waveform in onboard memory. If streaming is enabled, you can write more data than the allocated waveform size in ...

Calculates calibration constants pertaining to main analog path output impedance. During external calibration, you can put the waveform generator in different configurations and take measurements of the ...

Configures the waveform generator properties that affect arbitrary sequence generation, selecting the arbitrary sequence to produce and setting the gain and offset. The waveform generator must not be in ...

Takes waveform data from a specified Hierarchical Waveform Storage (HWS) file and creates an onboard waveform for use in arbitrary waveform or arbitrary sequence output modes. The waveform generator must ...

Returns the date and time of the last successful self-calibration. Not supported Not supported in VIs that run in a web application niFgen Get Self Cal Last Date And Time.vi :/nifgenlv.chm::/niFgen_Get_Self_Cal_Last_Date_and_Time.html ...

Creates and initializes a special NI-FGEN external calibration session. Flags are set that allow you to program an external calibration procedure using calibration-specific properties and nodes. However, ...

Configures the waveform generator to begin oscillator frequency calibration. Not supported Not supported in VIs that run in a web application niFgen Initialize Oscillator Frequency Calibration.vi :/nifgenlv.chm::/niFgen_Initialize_Oscillator_Frequency_Calibr.html ...

Creates and returns a new NI-FGEN session to the specified channel of a waveform generator that is used in all subsequent NI-FGEN calls. Optionally sets the initial state of session properties Range Check, ...

Takes one or more voltage measurements from the onboard calibration ADC and returns their average value. The signal that the ADC actually measures can be specified using the Cal ADC Input property. The ...

Calculates calibration constants pertaining to direct analog path output impedance. During external calibration, you can put the waveform generator in different configurations and take measurements of ...

Calculates calibration constants pertaining to flatness. During external calibration, the waveform generator is configured with the different analog settings, and measurements are taken of the resulting ...

Removes all previously created arbitrary waveforms, sequences, and scripts from the waveform generator memory and invalidates all waveform references, sequence references, and waveform names. The waveform ...

Aborts any previously initiated waveform generation. Not supported Not supported in VIs that run in a web application niFgen Abort Generation.vi :/nifgenlv.chm::/niFgen_Abort_Generation.html session ...

Use the NI-FGEN ADC control nodes only when following the calibration procedure of the waveform generator.

Calculates calibration constants pertaining to the gain and offset of the onboard calibration ADC. During external calibration, you can generate voltages and measure them both externally and with the calibration ...

Calculates calibration constants pertaining to the gain of the direct analog path. During external calibration, you can put the waveform generator in different configurations; program different gain and ...

Calculates calibration constants pertaining to direct analog path output impedance. During external calibration, you can put the waveform generator in different configurations and take measurements of ...

Calculates calibration constants pertaining to the postamplifier gain and offset of the main analog path. During external calibration, you can put the waveform generator in different configurations; program ...

Calculates calibration constants pertaining to the preamplifier gain of the main analog path. During external calibration, you can put the waveform generator in different configurations; program different ...

Calculates calibration constants pertaining to the preamplifier gain of the main analog path. During external calibration, you can put the waveform generator in different configurations; program different ...

Specifies the initial size of a named waveform so that it can be allocated in onboard memory before loading the associated data. Not supported Not supported in VIs that run in a web application After this ...

Use the NI-FGEN analog output nodes only when following the calibration DC gain and offset portion of the waveform generator calibration procedure.

Use the NI-FGEN arbitrary waveform nodes to configure, define, and clear an arbitrary waveform.

Use the NI-FGEN arbitrary sequence waveform nodes to configure, define, and clear an arbitrary sequence.

Use the NI-FGEN calibration nodes to calibrate NI waveform generators. Different waveform generator models use different calibration nodes. Refer to your waveform generator calibration procedure for more ...

Changes the password that is required to initialize an external calibration session. Not supported Not supported in VIs that run in a web application niFgen Change Ext Cal Password.vi :/nifgenlv.chm::/niFgen_Change_Ext_Cal_Password.html ...

Removes all previously created arbitrary waveforms, sequences, and scripts from the waveform generator memory and invalidates all waveform references, sequence references, and waveform names. The waveform ...

Showing 1-30 of 155 results