Filtered Results

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

You can use sample clock timing for digital I/O on the following devices. There is no dedicated onboard sample clock for digital I/O on these devices. You must use a different clock, typically the AI or ...

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain System class properties. You can select other classes from the node on the diagram.

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A DAQmx property node preselected to contain System class properties. You can select other classes from the node on the diagram.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Performs external calibration adjustment on a DSA device with the specified gain and coupling configuration. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Creates a timing source that uses the signal you specify to determine when to send ticks to a Timed Loop. You must create a task that can generate the signal and wire that task to the task/channels in ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values ...

Creates channel(s) that use an RTD to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs ...

Creates a task and adds virtual channels to that task if you specify them in the global virtual channels input. If you specify a task to copy, this node duplicates the configuration of the specified task ...

Writes one or more unscaled 16-bit unsigned integer samples to a task that contains one or more analog output channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Configures the task to start acquiring or generating samples when an analog signal enters or leaves a range you specify. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Writes the specified value to the DAC on the specified physical channel(s) for an NI PXIe-4322. This device requires a sweep of values obtained from the calibration procedure. LabVIEW NXG does not support ...

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires current excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires voltage excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When you use ...

Writes multiple raw, 32-bit signed integer samples to a task. Use this instance for devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Writes multiple raw, 8-bit unsigned integer samples to a task. Use this instance for devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Specifies for NI-DAQmx to map hardware registers to the memory space of the application, if possible. Normally, NI-DAQmx maps hardware registers to memory accessible only to the kernel. Mapping the registers ...

Specifies the order of the digital filter. Not supported Not supported in VIs that run in a web application 30C0 attr30C0.html

Specifies the maximum period (in seconds) in which the device will recognize signals. For frequency measurements, a signal with a higher period than the one set in this property will return 0 Hz. For duty ...

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 21EC attr21EC.html

Specifies the data transfer mode for the device. Not supported Not supported in VIs that run in a web application DMA 10054 Direct Memory Access. Data transfers take place independently from the application. ...

Showing 1-30 of 2163 results
1 of 73 pages