The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...
You can use sample clock timing for digital I/O on the following devices. There is no dedicated onboard sample clock for digital I/O on these devices. You must use a different clock, typically the AI or ...
The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...
A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...
On an X Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...
Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.
Specifies the sensitivity of the accelerometer. This value is in the units you specify with AI.Accel.SensitivityUnits. Refer to the sensor documentation to determine this value. Not supported Not supported ...
Specifies the last date and time that the channel underwent a channel calibration. Not supported Not supported in VIs that run in a web application 229A attr229A.html
Specifies in ohms the resistance of the wires that lead to the sensor. Not supported Not supported in VIs that run in a web application 17EE attr17EE.html
Specifies the number of bits to return in a raw sample when AI.RawDataCompressionType is set to Lossy LSB Removal. Not supported Not supported in VIs that run in a web application 22D9 attr22D9.html
Specifies whether to apply a digital filter to the AI Convert Clock. Not supported Not supported in VIs that run in a web application 2EDC attr2EDC.html
Indicates the maximum convert rate supported by the task, given the current devices and channel count. This rate is generally faster than the default AI Convert Clock rate selected by NI-DAQmx, because ...
Specifies the sentinel value returned when the No New Sample Behavior is set to Sentinel Value. Not supported Not supported in VIs that run in a web application 3094 attr3094.html
Specifies the polarity of the pulses at the output terminal of the counter when CtrOutEvent.OutputBehavior is Pulse. NI-DAQmx ignores this property if CtrOutEvent.OutputBehavior is Toggle. Not supported ...
Specifies the terminal of the signal to use as the timebase of the digital filter. Not supported Not supported in VIs that run in a web application 2ED4 attr2ED4.html
Specifies the terminal to which to route the Divided Sample Clock Timebase. Not supported Not supported in VIs that run in a web application 21A1 attr21A1.html
Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. When ...
Creates channel(s) to generate digital pulses defined by the amount of time the pulse is at a high state and the amount of time the pulse is at a low state. The pulses appear on the default output terminal ...
Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...