Filtered Results

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

You can use sample clock timing for digital I/O on the following devices. There is no dedicated onboard sample clock for digital I/O on these devices. You must use a different clock, typically the AI or ...

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A DAQmx property node preselected to contain System class properties. You can select other classes from the node on the diagram.

Creates channels to measure two-dimensional strain using a rosette strain gage. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Strain-Rosette ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. When you ...

Creates a channel that uses a linear encoder to measure linear position. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this ...

Specifies whether to apply a digital filter to the digital output of the analog triggering circuitry (the Analog Comparison Event). When enabled, the analog signal must stay within the trigger window for ...

Device range refers to the minimum and maximum analog signal levels that the ADC can digitize. Many measurement devices can select from several ranges by changing from unipolar mode to bipolar mode or ...

On a DSA device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is generated from the internal calibration multiplexer. The channels available on this multiplexer ...

On an NI 4300 or NI 433x device, you can either acquire a signal present on the I/O connector, or you can acquire an onboard signal, via an internal multiplexer. The channels available on this multiplexer ...

You can measure strain with a strain gage, which is a device with electrical resistance that varies in proportion to the amount of strain in the device, and with signal conditioning. When using a strain ...

Requirement I/O needs to be hardware-timed. All output values need to simultaneously update at the arrival of the sample clock edge. The application uses the Timed Loop. Solution Use the DAQmx Create Timing ...

Creates channel(s) that use an IEPE force sensor to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not ...

Returns the reference values to be measured by a reference device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 4322 Calibration Adjustment Points.vi ...

Creates channel(s) to measure resistance. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires voltage excitation. You must configure the physical channel(s) with TEDS information to use ...

Creates channel(s) to measure acceleration. Use this mode for custom sensors that require excitation. You can use the excitation to scale the measurement. LabVIEW NXG does not support FPGA devices Not ...

Creates channel(s) that use a sensor with charge output. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Acceleration-Accelerometer).vi ...

Creates channel(s) that use an LVDT to measure linear position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-LVDT).vi :/lvdaqmx.chm::/DAQmx ...

Sets up external calibration for an NI 9218 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Setup 9218 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Sets up external calibration for an NI 9219 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Setup 9219 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Showing 1-30 of 2160 results
1 of 72 pages