Filtered Results

You can use sample clock timing for digital I/O on the following devices. There is no dedicated onboard sample clock for digital I/O on these devices. You must use a different clock, typically the AI or ...

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A DAQmx property node preselected to contain System class properties. You can select other classes from the node on the diagram.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Writes a single sample of Boolean values to each channel in a task that contains multiple digital output channels. Each channel in the task can contain only one digital line. LabVIEW NXG does not support ...

Specifies the second physical value, corresponding to AI.Bridge.TwoPointLin.Second.ElectricalVal. Specify this value in the unit indicated by AI.Bridge.PhysicalUnits. Not supported Not supported in VIs ...

Specifies the amount of filter delay that gets removed if AI.RemoveFilterDelay is enabled. This delay adjustment is in addition to the value indicated by AI.FilterDelay. This delay adjustment is in the ...

Specifies whether to apply the open thermocouple detection bias voltage to the channel. Changing the value of this property on a channel may require settling time before the data returned is valid. To ...

Specifies the units to use to return frequency measurements. Not supported Not supported in VIs that run in a web application Hz 10373 Hertz. Ticks 10304 Timebase ticks. From Custom Scale 10065 Units a ...

Specifies the distance to measure for each pulse the encoder generates on signal A or signal B. This value is in the units you specify with CI.LinEncoder.Units. Not supported Not supported in VIs that ...

Specifies the minimum value you expect to measure. This value is in the units you specify with a units property. When you query this property, it returns the coerced minimum value that the hardware can ...

Specifies the divisor to apply to the signal you connect to the counter source terminal. Pulse generations defined by frequency or time take this setting into account, but pulse generations defined by ...

Specifies if DAQmx Wait for Next Sample Clock and DAQmx Read convert late errors to warnings. NI-DAQmx returns no late warnings or errors until the number of warmup iterations you specify with NumOfWarmupIters ...

Device ID Device Name 0x0160 NI PCI-DIO-96 0x0162 NI PCI-MIO-16XE-50 0x0245 NI DAQCard-6036E 0x02C4 NI DAQCard-6062E 0x0301 NI SCXI-1126 0x0302 NI SCXI-1121 0x0303 NI SCXI-1129 0x0304 NI SCXI-1120 0x0306 ...

On an S Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

In physical channel names, cDAQ1Mod1 is the default device name for a C Series device plugged into a USB or Standalone NI CompactDAQ chassis, where cDAQ1 is the default chassis device name, and Mod1 refers ...

When querying DAQmx Device and DAQmx Physical Channel attributes/properties with C Series devices, the supported attributes/properties depend on the slot you plug a device into. If the device is not in ...

Creates a channel that uses a linear encoder to measure linear velocity. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this ...

Creates a channel that measures the amount of time between the rising or falling edge of one digital signal and the rising or falling edge of another digital signal. With the exception of devices that ...

Creates a channel to measure the angular velocity of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical ...

Gets the available connections on an SC Express accessory for the specified physical channel(s). Connections specify how channels on the SC Express accessory should be configured. The resulting configuration ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Reads one or more raw, 32-bit unsigned integer samples from a task. Use this instance with devices that use 32-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When you use ...

Showing 1-30 of 2006 results
1 of 67 pages