Filtered Results

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

You can use sample clock timing for digital I/O on the following devices. There is no dedicated onboard sample clock for digital I/O on these devices. You must use a different clock, typically the AI or ...

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

Creates channel(s) that measure voltage ratios from a Wheatstone bridge. Use this instance with bridge-based sensors that measure phenomena other than strain, force, pressure, or torque, or that scale ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When ...

Wait until the specified timestamp has a value. Use this node to ensure the timestamp has a valid value to prevent an error when querying a timestamp value. LabVIEW NXG does not support FPGA devices Not ...

Writes one or more waveforms to a task that contains one or more analog output channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Write (Analog ...

Specifies in which unit to return voltage ratios from the channel. Not supported in VIs that run in a web application Volts/Volt 15896 Volts per volt. mVolts/Volt 15897 Millivolts per volt. From Custom ...

Specifies the units of AI.Accel.Charge.Sensitivity. Not supported in VIs that run in a web application PicoCoulombs per g 16099 PicoCoulombs per g. PicoCoulombs per m/s^2 16100 PicoCoulombs per m/s^2 . ...

Specifies the units to use to return charge measurements from the channel. Not supported in VIs that run in a web application From Custom Scale 10065 Units a custom scale specifies. If you select this ...

Specifies the FM deviation in hertz per volt when AO.FuncGen.ModulationType is FM. Not supported in VIs that run in a web application 2A23 attr2A23.html

Specifies in ohms the impedance of the analog output stage of the device. Not supported in VIs that run in a web application 1490 attr1490.html

Specifies the logic level behavior on the count reset line. Not supported in VIs that run in a web application Logic Level Pull-up 16064 High logic. None 10230 Supply no excitation to the channel. 30A0 ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported in VIs that run in a web application 21E8 attr21E8.html

Specifies the position of the encoder when the measurement begins. This value is in the units you specify with CI.LinEncoder.Units. Not supported in VIs that run in a web application 915 attr915.html

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported in VIs that run in a web application 2212 attr2212.html

Adjusts the external calibration constants for an NI PXIe-4339 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 4339 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9225 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9225 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates a channel to measure current RMS, the average (mean) power of the acquired current. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel ...

Adjusts the external calibration constants for the analog input section of a DSA device. You must connect a known voltage to the device and specify that voltage with reference voltage. LabVIEW NXG does ...

Creates a channel to measure pulse specifications, returning the measurements as pairs of high time and low time. With the exception of devices that support multi-counter tasks, you can create only one ...

Creates a virtual channel, or set of virtual channels, and adds them to a task. You must configure the physical channel(s) with TEDS information to use this node. If you use this node within a loop without ...

Creates and configures a task that controls the watchdog timer of a device. The timer activates when you start the task. Use the digital physical channel expiration states input to set expiration states ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Showing 1-30 of 1955 results
1 of 66 pages