You can use sample clock timing for digital I/O on the following devices. There is no dedicated onboard sample clock for digital I/O on these devices. You must use a different clock, typically the AI or ...

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

Creates a channel that uses a linear encoder to measure linear position. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this ...

Creates a channel to measure the width of a digital pulse. starting edge determines whether to measure a high pulse or low pulse. With the exception of devices that support multi-counter tasks, you can ...

Creates channel(s) that use an IEPE force sensor to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not ...

Creates channel(s) that use(s) an accelerometer to measure acceleration. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Acceleration-Accelerometer).vi ...

Creates channel(s) to measure voltage. Use this instance for custom sensors that require excitation. You can use the excitation to scale the measurement. LabVIEW NXG does not support FPGA devices Not supported ...

Configures the task to stop the acquisition when the device acquires all pretrigger samples; an analog signal reaches the level you specify; and the device acquires all post-trigger samples. LabVIEW NXG ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Sets up external calibration for an NI 9219 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Setup 9219 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires voltage excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

In physical channel names, cDAQ1Mod1 is the default device name for a C Series device plugged into a USB or Standalone NI CompactDAQ chassis, where cDAQ1 is the default chassis device name, and Mod1 refers ...

Device ID Device Name 0x0160 NI PCI-DIO-96 0x0162 NI PCI-MIO-16XE-50 0x0245 NI DAQCard-6036E 0x02C4 NI DAQCard-6062E 0x0301 NI SCXI-1126 0x0302 NI SCXI-1121 0x0303 NI SCXI-1129 0x0304 NI SCXI-1120 0x0306 ...

When performing a buffered time measurement of a digital signal, the initial sample is often invalid. The following devices detect such samples and discard them. Bus-powered M Series USB devices Parallel ...

On an X Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

If you measure the digital frequency or the period of a counter signal, you can use this two-counter method to measure signals with large ranges. This method is useful when you have a widely varying signal ...

The following example illustrates how to create a task with the API: Problem Create an NI-DAQmx task to measure temperature in the range 50°C to 200°C using a J-type thermocouple that is wired to channel ...

Reads a waveform from a task that contains a single analog input channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Analog Wfm 1Chan NSamp).vi ...

Waits for the measurement or generation to complete. Use this node to ensure that the specified operation is complete before you stop the task. LabVIEW NXG does not support FPGA devices Not supported in ...

Internal Channels for the NI 9210 Device Internal Channel Name Description _aignd_vs_aignd A referenced single-ended terminal with the positive and negative terminals both connected to the ground reference ...

Adds a cDAQ Sync connection between devices. The connection is not verified. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Add cDAQ Sync Connection.vi ...

Adjusts the external calibration constants for an NI PXIe-4303 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 4303 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9226 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9226 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9232 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9232 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use an LVDT to measure linear position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-LVDT).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a table of electrical values and the corresponding physical values. When you ...

Creates channel(s) to measure voltage. If the measurement requires the use of internal excitation or you need excitation to scale the voltage, use the Custom Voltage with Excitation measurement type for ...

Creates channel(s) to measure current. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...