The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

You can use sample clock timing for digital I/O on the following devices. There is no dedicated onboard sample clock for digital I/O on these devices. You must use a different clock, typically the AI or ...

The following tables lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals. To change the PFI input for a measurement, use ...

Adjusts the external calibration gain constants for an NI 9207 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9207 Gain Calibration.vi ...

Adjusts the external calibration offset constants for an NI 9207 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9207 Offset Calibration.vi ...

Adjusts the external calibration offset constants for an NI 9208 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9208 Offset Calibration.vi ...

Use the DAQmx - Data Acquisition Nodes with NI-DAQ hardware devices to develop instrumentation, acquisition, and control applications. Refer to the NI-DAQmx Readme for a complete listing of devices that ...

Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9217 Calibration ...

Reads a single floating-point sample from each channel in a task that contains one or more analog input channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Configures TDMS file logging for the task. To maximize performance and to minimize file size, DAQmx TDMS files store raw data and scaling information separately, and do not need defragmentation. Attempting ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Creates channel(s) that use an RTD to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs ...

Creates channel(s) that use a thermocouple to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates channel(s) that use(s) an accelerometer to measure acceleration. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Acceleration-Accelerometer).vi ...

Creates channel(s) that use a sensor with charge output. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Acceleration-Accelerometer).vi ...

Creates a channel to measure current RMS, the average (mean) power of the acquired current. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When you use ...

Writes the specified binary value to the DAC on the specified physical channel. This module requires a sweep of DAC values obtained from the DAQmx Get 9263 Calibration Adjustment Points node. LabVIEW NXG ...

Writes multiple raw, 16-bit signed integer samples to a task. Use this instance for devices that use 16-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Configures when the DAQ device transfers data to a peripheral device, using the onboard Sample Clock of the DAQ device to control burst handshake timing, and exporting that clock for use by the peripheral ...

Configures the task to acquire samples on the rising and/or falling edges of the lines or ports you specify. To detect both rising and falling edges on a line or port, wire the name of that line or port ...

Writes multiple raw, 8-bit unsigned integer samples to a task. Use this instance for devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications do not provide a polynomial for scaling or a table of electrical and physical values. ...

S Series and X Series simultaneous sampling devices use simultaneous sampling. M Series, E Series, all other X Series devices use multiplexed sampling. C Series devices in an NI CompactDAQ chassis use ...

Adjusts the external calibration constants for an NI 9238 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9238 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Performs external calibration adjustment on a DSA device with the specified gain and coupling configuration. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Creates channels to measure two-dimensional strain using a rosette strain gage. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Strain-Rosette ...

Creates channel(s) to measure voltage. Use this instance for custom sensors that require excitation. You can use the excitation to scale the measurement. LabVIEW NXG does not support FPGA devices Not supported ...