Filtered Results

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A DAQmx property node preselected to contain System class properties. You can select other classes from the node on the diagram.

Specifies the units of AI.Accel.Charge.Sensitivity. Not supported Not supported in VIs that run in a web application PicoCoulombs per g 16099 PicoCoulombs per g. PicoCoulombs per m/s^2 16100 PicoCoulombs ...

Specifies the decibel reference level in the units of the channel. When you read samples as a waveform, the decibel reference level is included in the waveform attributes. Not supported Not supported in ...

Specifies the sensitivity of the accelerometer. This value is in the units you specify with AI.Accel.SensitivityUnits. Refer to the sensor documentation to determine this value. Not supported Not supported ...

Specifies the units to use to return proximity measurements from the channel. Not supported Not supported in VIs that run in a web application Meters 10219 Meters. Inches 10379 Inches. From Custom Scale ...

Specifies the units to use to return acceleration measurements from the channel. Not supported Not supported in VIs that run in a web application g 10186 1 g is approximately equal to 9.81 m/s/s. m/s^2 ...

Specifies the actual amount of excitation supplied by an internal excitation source. If you read an internal excitation source more precisely with an external device, set this property to the value you ...

Specifies whether to synchronize the AC excitation source of the channel to that of another channel. Synchronize the excitation sources of multiple channels to use multichannel sensors. Set this property ...

Specifies the number of leads on the LVDT or RVDT. Some sensors require you to tie leads together to create a four- or five- wire sensor. Refer to the sensor documentation for more information. Not supported ...

Specifies the timing mode of the ADC when AI.ADCTimingMode is Custom. Not supported Not supported in VIs that run in a web application 2F6B attr2F6B.html

Specifies the ADC timing mode, controlling the tradeoff between speed and effective resolution. Some ADC timing modes provide increased powerline noise rejection. On devices that have an AI Convert clock, ...

Specifies the amount of attenuation to use. Not supported Not supported in VIs that run in a web application 1801 attr1801.html

Specifies how often to measure ground. NI-DAQmx subtracts the measured ground voltage from every sample. Not supported Not supported in VIs that run in a web application None 10230 Do not perform an autozero. ...

Specifies the number of seconds to wait after a handshake cycle before starting a new handshake cycle. Not supported Not supported in VIs that run in a web application 22C2 attr22C2.html

Specifies the asserted level of the Handshake Trigger. Not supported Not supported in VIs that run in a web application High 10192 High state. Low 10214 Low state. 22B9 attr22B9.html