Filtered Results

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A DAQmx property node preselected to contain System class properties. You can select other classes from the node on the diagram.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Specifies the corresponding filter enable/disable state. Not supported Not supported in VIs that run in a web application 2FED attr2FED.html

Specifies the corresponding filter frequency (cutoff or center) of the filter response. Not supported Not supported in VIs that run in a web application 2FED attr2FED.html

Specifies the corresponding filter order and defines the slope of the filter response. Not supported Not supported in VIs that run in a web application 2FED attr2FED.html

Specifies the corresponding filter response and defines the shape of the filter response. Not supported Not supported in VIs that run in a web application 2FED attr2FED.html

Indicates the amount of time between when the ADC samples data and when the sample is read by the host device. This value is in the units you specify with AI.FilterDelayUnits. You can adjust this amount ...

Specifies the amount of filter delay that gets removed if AI.RemoveFilterDelay is enabled. This delay adjustment is in addition to the value indicated by AI.FilterDelay. This delay adjustment is in the ...

Specifies the units of AI.FilterDelay and AI.FilterDelayAdjustment. Not supported Not supported in VIs that run in a web application Seconds 10364 Seconds. Sample Clock Periods 10286 Sample Clock Periods. ...

Specifies the sensitivity of the IEPE force sensor connected to the channel. Specify this value in the unit indicated by AI.Force.IEPESensor.SensitivityUnits. Not supported Not supported in VIs that run ...

Specifies the units for AI.Force.IEPESensor.Sensitivity. Not supported Not supported in VIs that run in a web application mVolts/N 15891 Millivolts per newton. mVolts/lb 15892 Millivolts per pound. 2F82 ...

Specifies in which unit to return force or load measurements from the channel. Not supported Not supported in VIs that run in a web application Newtons 15875 Newtons. Pounds 15876 Pounds. kgf 15877 Kilograms-force. ...

Specifies whether to read from the channel if it is a cold-junction compensation channel. By default, DAQmx Read does not return data from cold-junction compensation channels. Setting this property to ...

Specifies in volts a window below AI.Freq.ThreshVoltage. The input voltage must pass below AI.Freq.ThreshVoltage minus this value before NI-DAQmx recognizes a waveform repetition at AI.Freq.ThreshVoltage. ...

Specifies the voltage level at which to recognize waveform repetitions. You should select a voltage level that occurs only once within the entire period of a waveform. You also can select a voltage that ...

Specifies the units to use to return frequency measurements from the channel. Not supported Not supported in VIs that run in a web application Hz 10373 Hertz. From Custom Scale 10065 Units a custom scale ...

Showing 1-20 of 2037 results