Adjusts the external calibration constants for an SCXI-1521 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 1521 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates a timing source that uses a combination of the sample clock and the specified sleep time to determine when to send ticks to a Timed Loop. You must create an analog input task that uses sample clock ...

Creates a timing source that sends ticks to a Timed Loop on rising and/or falling edges of one or more digital lines. You can use this node only with devices that support digital change detection. For ...

Adjusts the external calibration constants for an NI 9226 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9226 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) that use an IEPE force sensor to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not ...

Creates channel(s) that use an LVDT to measure linear position. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates channel(s) that use an RVDT to measure angular position. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates channel(s) that use a microphone to measure sound pressure. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Sound Pressure-Microphone).vi ...

Creates channel(s) to measure resistance. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates channel(s) that use a microphone to measure sound pressure. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Detects and configures cDAQ Sync connections between devices. Stop all NI-DAQmx tasks running on the devices prior to running this node, because any running tasks cause auto-configuration to fail. Auto-configure ...

Creates channel(s) that use an RTD to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs ...

Adjusts the external calibration constants for an NI 9244 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9244 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9246 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9246 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9247 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9247 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9250 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9250 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9251 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9251 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) to measure voltage. You must configure the physical channel(s) with TEDS information to use this node. If the measurement requires the use of internal excitation or you need excitation ...

Adjusts the external calibration constants for an NI 9263 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9263 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9264 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9264 Calibration.vi :/lvdaqmx.chm::/DAQmx ...