Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Characteristics describe values that are relevant to the ...

You must connect the cRIO-904 x grounding terminal to the grounding electrode system of the facility. What to Use Ring lug Wire, 1.3 mm 2 (16 AWG) or larger Screwdriver, Phillips #2 What to Do Complete ...

Complete the following steps to install software on the cRIO-904 x . In MAX, expand your system under Remote Systems. Right-click Software . Select Add/Remove Software to launch the LabVIEW Real-Time Software ...

Complete the following steps to set a system password. In MAX, click the Login button on the toolbar. Enter admin in the User name field. Leave the Password field blank. Note There is no default password ...

The following table describes the STATUS LED indicators. Table 3. STATUS LED Indicators LED Color LED Pattern Indication Yellow Blinks twice and pauses The cRIO-904 x is in safe mode. Software is not installed, ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

The following figure shows the reset behavior of the cRIO-904 x . Figure 6. Reset Button Behavior Press and hold RESET button fo r ≥ 5 s Press and hold RESET button for < 5 s Run Mode Safe Mode

Complete the following steps to run a test panel in Measurement & Automation Explorer (MAX) to confirm that your cRIO-904x is communicating with your system.

Notice To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. Touch the antistatic package ...

Visit the following topics for information on how to create a new LabVIEW Project configured with the cRIO-904x, and how to deploy the C Series module in the Real-Time, Real-Time Scan (IO Variables), or ...

Put the cRIO-904 x in safe mode and enable the RS-232 serial port by holding the RESET button down for 5 seconds. The STATUS LED starts blinking three times every few seconds. Use the RS-232 serial port ...

If you do not currently have any NI software installed on your host computer, see the Install Software section for details on required software and in which order to install it. If you have some NI software ...

Verify that the following items are included in the cRIO-904 x controller kit. Figure 1. cRIO-904 x Kit Contents 1 3 4 6 8 5 7 2 Controller (4-Slot or 8-Slot) USB Type-A Male to USB Type-C Male Cable Power ...

Complete the following steps to deploy your C Series module in a new program mode in MAX. Launch MAX on the host computer. Expand Remote Systems in the configuration tree and locate your cRIO-904 x system. ...

Add an exception for MAX to your network firewall or other security software by completing the following steps: On Windows 7, select Start » Control Panel » System and Security » Windows Firewall » Allow ...