The LEDs may not light until the module has been configured in MAX. Before proceeding, verify that the NI 6544/6545/6547/6548 appears in MAX. If the ACCESS LED fails to light after you power on the chassis, ...

During dynamic acquisition, the device under test (DUT) generating the signals must have a matched source impedance as close to 50 Ω as possible in order to minimize signal reflections and maintain optimal ...

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI 6544/6545/6547/6548 front panel exposes the following connections: Three SMA connectors named CLK IN, PFI 0 , and CLK OUT One 68-pin VHDCI connector named DIGITAL DATA & CONTROL, or DDC Figure 2. ...

To verify your device configuration, use the device test panel in MAX to generate simple digital data using the NI 6544/6545/6547/6548.

In the MAX configuration tree, expand Devices and Interfaces . Expand the Chassis tree to see the list of installed hardware, and press to refresh the list. If the module is still not listed, power ...

To locate programming examples, refer to the following table. Table 6. NI-HSDIO Example Locations Application Development Environment (ADE) Location LabVIEW or LabWindows/CVI Within LabVIEW or LabWindows/CVI, ...

Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI 6544/6545/6547/6548 . The NI 6544/6545/6547/6548 is a digital ...

Notice To prevent damage to the NI 6544/6545/6547/6548 caused by ESD or contamination, handle the module using the edges or the metal bracket. Ensure the AC power source is connected to the chassis before ...

You must be an Administrator to install NI software on your computer. Install an ADE, such as LabVIEW or LabWindows™/CVI™. Download the driver software installer from ni.com/downloads . NI Package Manager ...

The kit contains the following items: NI-HSDIO instrument driver software media, which installs the following: NI-HSDIO driver NI Script Editor NI Digital Waveform Generator/Analyzer Help NI PXIe-6544/6545/6547/6548 ...

Restart the system. Launch MAX, and perform the self-test again. Power off the chassis. Reinstall the failed module in a different slot. Power on the chassis. Perform the self-test again. Parent topic: ...

You can generate or acquire data using the NI-HSDIO instrument driver to program the NI 6544/6545/6547/6548 in the supported ADE of your choice.

Operating Environment Ambient temperature range 0 °C to 40 °C Relative humidity range 10% to 90%, noncondensing Maximum altitude 2,000 m ( 800 mbar ) (at 25 °C ambient temperature) Pollution Degree 2 Indoor ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

If an issue persists after you complete a troubleshooting procedure, search our KnowledgeBase for additional information our technical support engineers create as they answer common user questions and ...

Notice To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. Touch the antistatic package ...