Filtered Results

U.S. (UL) Class I, Division 2, Groups A, B, C, D, T4 ; Class I, Zone 2 , AEx nA IIC T4 Gc Canada (C-UL) Class I, Division 2, Groups A, B, C, D, T4 ; Class I, Zone 2

Dimensions Visit ni.com/dimensions and search by module number. Weight Approx. 144 g (5.0 oz) Parent topic: NI-9866 Specifications

Power consumption from chassis 1 W maximum (active mode) Thermal dissipation (at 70 °C ) 1.25 W maximum (active mode) Parent topic: NI-9866 Specifications

The NI-9866 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07 ATEX 0626664X and is IECEx UL 14.0089X certified. Each NI-9866 is marked II 3G and is suitable for use in Zone 2 hazardous locations, ...

Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and compromise the built-in safety protection. Attention Suivez ...

The maximum number of devices on a LIN bus is 16, per the LIN specification. Parent topic: Cabling Requirements for the NI 9866

The maximum allowable cable length is 40 m , per the LIN specification. Parent topic: Cabling Requirements for the NI 9866

LIN cables should meet the physical medium requirement of a bus RC time constant of 5 µs . For detailed formulas for calculating this value, refer to the Line Characteristics section of the LIN specification. ...

This section deals with cabling specifications, termination resistors, cable lengths, and the number of LIN nodes that can exist in a system. Parent topic: Overview

2014/34/EU; Potentially Explosive Atmospheres (ATEX) Parent topic: NI-9866 Specifications

5 40 e 中国RoHS — NI符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于NI中国RoHS合规性信息,请登录 ni.com/environment/rohs_china 。(For information about China RoHS compliance, go to ni.com/environment/rohs_china .) Parent topic: NI-9866 ...

This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Basic immunity EN 55011 ...

NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment ...

Refer to the manual for the chassis you are using for more information about meeting these specifications. Operating temperature ( IEC 60068-2-1 , IEC 60068-2-2 ) -40 °C to 70 °C Storage temperature ( ...

The NI-9866 has one full-featured LIN port that is isolated from the other modules in the system. The port has a LIN controller that is fully compliant with the LIN 1.3/2.0/2.1/2.2 Specification. The port ...

This document explains how to connect to the NI-9866 . Note Before you begin, read the NI-9866 Safety, Environmental, and Regulatory Information document on ni.com/manuals and complete the software and ...

The NI-9866 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2 , AEx nA IIC T4 Gc and Ex nA IIC T4 hazardous locations; and nonhazardous locations only. ...

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications ...

Transceiver NXP TJA1028 Max baud rate 20 kbps LIN bus lines voltage -40 to +40 VDC Supply voltage range (V SUP ) +8 to +18 VDC normal operation, -0.3 to +40 V absolute limits MTBF Contact NI for Bellcore ...

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No. ...

Showing 1-20 of 34 results