You can connect 2-, 3-, and 4-wire sourcing-output devices to the NI-9425 . NI 9425 + _ COM DI Sourcing-Output Device External Power Supply The NI-9425 channel registers as ON when the sourcing-output ...

Make sure that devices you connect to the NI-9425 are compatible with the module specifications. You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single ...

Located at n i . c o m / manuals Installs with the software CompactRIO NI CompactDAQ RELATED INFORMATION C Series Documentation & Resources n i .co m / info a cseriesdoc S er vi ces ni. c om/ s

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI-9425 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2 , AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations; and nonhazardous locations ...

The NI 9425 with spring terminal has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 12 ATEX 1202658X and is IECEx UL 14.0089X certified. The NI 9425 with DSUB has been evaluated as Ex nA IIC T4 ...

Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits ...

If your application is subject to high vibration, NI recommends that you use the cRIO-9940 backshell kit to protect connections to the NI-9425 with spring terminal . Parent topic: NI-9425 Connection Guidelines ...

Some products are approved for marine (shipboard) applications. To verify marine approval certification for a product, visit ni.com/product-certifications , search by model number, and click the appropriate ...

This document explains how to connect to the NI-9425 . In this document, the NI-9425 with spring terminal and the NI-9425 with DSUB are referred to inclusively as the NI-9425 . Note Before you begin, read ...

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 DI0 DI1 DI3 DI5

Ensure that the environment in which you are using the NI 9425 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C Operating humidity (IEC 60068-2-30) ...

Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and compromise the built-in safety protection. Attention Suivez ...

Connect only voltages that are within the following limits. Channel-to-channel Up to 8 channels simultaneously ±60 V maximum All channels simultaneously ±30 V maximum Isolation Channel-to-channel None ...

Connect only voltages that are within the following limits. Channel-to-channel Up to 8 channels simultaneously ±60 V maximum All channels simultaneously ±30 V maximum Isolation Channel-to-channel None ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

Compatible with 24 V logic levels DSUB or spring terminal connectivity 250 V RMS , CAT II , channel-to-earth isolation (spring terminal); 60 V DC , CAT I , channel-to-earth isolation (DSUB) Note In this ...

This document describes the range of software versions required for the aforementioned devices and links to the most recent documentation resources available at ni.com/manuals for each device. Note: Your ...

This document provides device specifications and instructions for installing and operating the sbRIO-9425.