CompactRIO NI CompactDAQ Located at ni.com/manuals RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Installs with the software NI 9215 Datasheet NI-RIO ...

BNC, screw terminal, or spring terminal connectivity 250 V RMS , CAT II , channel-to-earth isolation (screw terminal); 60 V DC , CAT I , channel-to-earth isolation (BNC) The NI-9215 is an analog input ...

This document explains how to connect to the NI-9215 . In this document, the NI-9215 with screw terminal , NI-9215 with spring terminal , and NI-9215 with BNC are referred to inclusively as the NI-9215 ...

If you need to clean the module, wipe it with a dry towel. Tip For two-dimensional drawings and three-dimensional models of the C Series module and connectors, visit ni.com/dimensions and search by module ...

AI0+ AI0- AI1+ AI1– AI2+ AI2– AI3+ AI3– NC COM 0 1 2 3 4 5 6 7 8 9 AI0+ AI0– AI1+ AI1– AI2+ AI2– AI3+ AI3– NC COM 0 1 2 3 4 5 6 7 8 9

Ensure that the environment in which you are using the NI 9215 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C Operating humidity (IEC 60068-2-78) ...

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications ...

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No. ...

Connect only voltages that are within the following limits. Channel-to-COM ±30 V maximum Isolation Channel-to-channel None Channel-to-earth ground Continuous 250 V RMS, Measurement Category II Withstand ...

+ – AI+ AI– Voltage Source NI 9215 with Screw/Spring Terminal COM Connect the ground signal to COM to keep the signal source within the common-mode voltage range. NI 9215 with BNC AI+ AI– + – Voltage Source ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

Connect only voltages that are within the following limits. AI+-to-AI- ±30 V maximum Isolation Channel-to-channel None Channel-to-earth ground Continuous 60 V DC, Measurement Category I Withstand 1,500 ...

This product meets the essential requirements of applicable European Directives, as follows: 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC) 2014/34/EU; ...

Make sure that devices you connect to the NI-9215 are compatible with the module specifications. You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single ...

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

1 M Ω Resistor NI 9215 with Screw/Spring Terminal AI+ AI– COM Voltage Source + – Connect the negative lead to COM through a 1 MΩ resistor to keep the signal source within the common-mode voltage range. ...

Voltage Source + – AI+ AI– COM NI 9215 with Screw/Spring Terminal COM NI 9215 with BNC AI+ AI– + – Parent topic: Overview

The NI-9215 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2 , AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations; and nonhazardous locations ...

The NI 9215 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 03 ATEX 0324020X and is IECEx UL 14.0089X certified. Each NI 9215 is marked II 3G and is suitable for use in Zone 2 hazardous