... Log in cRIO-9047 Specifications 1.60 GHz Quad-Core CPU, ... Controller cRIO-9047 Specifications cRIO-9047 Specifications ... Specifications cRIO-9047 class="topictitle1" id="GUID-60B711B1-E771-4855-85F3-F5FB4D ...

... Certifications cRIO-9047 Product Certifications cRIO-9047 Product ... ASSY, CRIO-9047, 1.6 GHZ QUAD-CORE, 4 GB DRAM, 4 GB ...

... Drawings cRIO-9047 Dimensional Drawings cRIO-9047 Dimensional ... for the cRIO-9047. 2D Dimensional Drawings PDF DXF 3D ...

... Volatility cRIO-9047 December 2017 Notice: This document ... later cRIO-9047 145051A-06L or later cRIO-9047 with ... Volatility cRIO-9047 December 2017 Notice: This document ...

You must connect the cRIO-904 x grounding terminal to the grounding electrode system of the facility. What to Use Ring lug Wire, 1.3 mm 2 (16 AWG) or larger Screwdriver, Phillips #2 What to Do Complete ...

Complete the following steps to install software on the cRIO-904 x . In MAX, expand your system under Remote Systems. Right-click Software . Select Add/Remove Software to launch the LabVIEW Real-Time Software ...

Complete the following steps to set a system password. In MAX, click the Login button on the toolbar. Enter admin in the User name field. Leave the Password field blank. Note There is no default password ...

The following table describes the STATUS LED indicators. Table 3. STATUS LED Indicators LED Color LED Pattern Indication Yellow Blinks twice and pauses The cRIO-904 x is in safe mode. Software is not installed, ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

The following figure shows the reset behavior of the cRIO-904 x . Figure 6. Reset Button Behavior Press and hold RESET button fo r ≥ 5 s Press and hold RESET button for < 5 s Run Mode Safe Mode

Complete the following steps to run a test panel in Measurement & Automation Explorer (MAX) to confirm that your cRIO-904x is communicating with your system.

Notice To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. Touch the antistatic package ...

Visit the following topics for information on how to create a new LabVIEW Project configured with the cRIO-904x, and how to deploy the C Series module in the Real-Time, Real-Time Scan (IO Variables), or ...