Filtered Results

Before you begin, you should understand the VeriStand Engine and the PCL execution mode steps. Launch the VeriStand Editor. In the Project Files pane, double-click a system definition file (.nivssdf). ...

Before you begin, add a model to the system definition. Use model execution channels to accomplish tasks such as manually starting the execution of a model rather than allowing it to execute upon deployment. ...

Open VeriStand. Create or open a VeriStand project. Click Configure... to open System Explorer. Click File New to open the New System Definition dialog box. Enter a System Definition name. Click OK. After ...

Before you begin, you should familiarize yourself with the Stimulus Profile Editor environment. Real-time sequences deploy to the target and can deterministically execute. Sequences test the UUT by reading ...

A VeriStand project contains at least one project file (.nivsprj), one system definition file (.nivssdf), and one screen file (.nivsscr or .nivsscreen). These files are used to configure, deploy, and interact ...

Before you begin, you might need to scale a channel when using a sensor that requires scaling from its voltage or current output into engineering units. Use your sensor's documentation for more information ...

Before you begin, identify your parameter’s type and scope. In VeriStand, parameters have two scopes. Target-level scope—VeriStand applies updates to all global parameter values with the same name in other ...

Before you begin, install the VeriStand Model Framework on the computer you are compiling the model. The framework adds tools you will use during the compile process. Determine what real-time operating ...

Open the Workspace. Select Screen Edit Mode to display the Workspace Controls palette and alignment grid. Click the Workspace Controls palette. Select Model Calibration Control. Choose one of the following ...

Before you begin, learn about the supported syntax for .txt files. Open a formatted .txt file. Create or open a second text file that updates parameters from the same model. This is the subscript file. ...

Before you begin, create a model header file. Browse to \VeriStand\\ModelInterface\custom\examples, create a copy of template.c, and give the copy a new name. is the drive ...

Add and configure alarms with the VeriStand Editor, System Explorer, and Workspace. Depending on your goal, access the following locations to add and configure alarms. Goal Location Add a new alarm to ...

Open the Workspace. Select Screen Edit Mode to display the Workspace Controls palette and alignment grid. Click the Workspace Controls palette and drag a control or indicator onto the alignment grid. In ...

Open a project in VeriStand. Depending on your hardware goal, complete any of the following tasks in System Explorer. Goal Task Adding and configuring an SLSC device Use SLSC devices to introduce signal ...

Depending on your goal, use an argument to send a command to the VeriStand Editor. Goal Argument Example Specify the VeriStand project to run. /nivsprj /nivsprj "\Examples\Stimulus Profile\Engine ...

Before you begin, choose a compiler. Launch Simulink software and load the model you want to convert. Select Simulation Model Configuration Parameters . In the Model Configuration Parameters dialog box, ...

Before you begin, add a channel or alias to the system definition. Launch the VeriStand Editor. In the Project Files pane, right-click the system definition file (.nivssdf), and click Mapping Diagram. ...

The text files must be in the following format.parameter1 delimiter value1 parameter2 delimiter value2 ...The text file cannot contain any column headers. The following table describes valid entries for ...

Before you begin, you must add a model to the system definition. The VeriStand Editor will reference the alias instead of the full channel path.The alias' location in the system definition cannot be changed ...

VeriStand applies linear interpolation to values between the table values. This ensures that values scale proportionally. Launch the VeriStand Editor. In the Project Files pane, double-click a system definition ...

Showing 1-20 of 402 results
1 of 21 pages