Filtered Results

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Thermocouples are the most commonly used temperature sensors. A thermocouple is created when two dissimilar metals touch and the contact point produces a small open-circuit voltage that corresponds to ...

Use the Write TEDS Data function/VI to write data to a TEDS sensor. The TEDS data must be in a virtual TEDS file or in a bitstream constructed according to the IEEE 1451.4 specification. National Instruments ...

Requirement The I/O tasks do not support hardware-timed operations. Solution Apply software timing to your time-critical loop by using the Timed Loop in LabVIEW or asynchronous timers in LabWindows/CVI. ...

When a task-based route gets created and released, it does not necessarily go away. The hardware resources associated with the route are released, but the configuration might remain so that glitches are ...

The idle state, which controls the pulse train polarity, is applied to the signal when a task transitions to the Committed state (which happens automatically when the task starts). The idle state polarity ...

This section describes sample applications that demonstrate the functionality for hardware-timed single-point operations on real-time platforms. Most of these applications use the Wait For Next Sample ...

Writes one or more unscaled, 32-bit signed integer samples to a task that contains one or more analog output channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Writes multiple raw, 32-bit signed integer samples to a task. Use this instance for devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Writes multiple raw, 32-bit signed integer samples to a task. Use this instance for devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Indicates the number of time triggers available on the device. Not supported Not supported in VIs that run in a web application 2985 attr2985.html

Specifies the voltage level for the sensor's power supply. Not supported Not supported in VIs that run in a web application 21D9 attr21D9.html

Indicates whether there is an overcurrent condition on the channel. Not supported Not supported in VIs that run in a web application 21D9 attr21D9.html

Indicates the calibrated gain of the channel. Not supported Not supported in VIs that run in a web application 3065 attr3065.html

Indicates the coupling types supported by this device. Not supported Not supported in VIs that run in a web application AC 10045 Remove the DC offset from the signal. DC 10050 Allow NI-DAQmx to measure ...

Specifies the type of compression to apply to raw samples returned from the device. Not supported Not supported in VIs that run in a web application None 10230 Do not compress samples. Lossless Packing ...

Specifies whether to enable enhanced alias rejection. Leave this property set to the default value for most applications. Not supported Not supported in VIs that run in a web application 2294 attr2294.html ...

Specifies the units for AI.Force.IEPESensor.Sensitivity. Not supported Not supported in VIs that run in a web application mVolts/N 15891 Millivolts per newton. mVolts/lb 15892 Millivolts per pound. 2F82 ...

Showing 1-20 of 2310 results
1 of 116 pages