Filtered Results

A DAQmx property node preselected to contain Device class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

A DAQmx property node preselected to contain Timing class properties. You can select other classes from the node on the diagram.

Use the DAQmx Physical Channel properties to query information about physical channels. Use the DAQmx Channel properties to configure virtual channels.

A terminal is a named location where a signal is either generated (output or produced) or acquired (input or consumed). A terminal that can output only one signal is often named after that signal. A terminal ...

Writes new pulse frequency and duty cycle pairs to a counter output task that contains a single channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx ...

Configures the task to start acquiring or generating samples when an analog signal enters or leaves a range you specify. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires voltage excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When you use ...

Writes multiple raw, 8-bit unsigned integer samples to a task. Use this instance for devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Writes TEDS data to the TEDS sensor connected to the physical channel you specify. This node can write TEDS data from a 1D array of 8-bit unsigned integers or from a virtual TEDS file.

Writes one or more unscaled 16-bit unsigned integer samples to a task that contains one or more analog output channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Indicates the IDs of the templates in the bitstream in TEDS.BitStream. Not supported in VIs that run in a web application 228F attr228F.html

Specifies the sensitivity of the 4 wire DC voltage acceleration sensor connected to the channel. This value is the units you specify with AI.Accel.4WireDCVoltage.SensitivityUnits. Refer to the sensor documentation ...

Specifies for NI-DAQmx to map hardware registers to the memory space of the application, if possible. Normally, NI-DAQmx maps hardware registers to memory accessible only to the kernel. Mapping the registers ...

Specifies the units of AO.Resolution. Not supported in VIs that run in a web application Bits 10109 Bits. 182B attr182B.html

Specifies the current limit, in amperes, for the voltage channel. Not supported in VIs that run in a web application 2A1D attr2A1D.html

Specifies in what units to generate voltage on the channel. Write data to the channel in the units you select. Not supported in VIs that run in a web application Volts 10348 Volts. From Custom Scale 10065 ...

Specifies on which edge of the input signal to begin pulse measurement. Not supported in VIs that run in a web application Rising 10280 Rising edge(s). Falling 10171 Falling edge(s). 2F05 attr2F05.html ...

Showing 1-20 of 2014 results
1 of 101 pages